Medicine
Technetium (99mTc) fanolesomab
A mouse antibody that made neutrophils glow: approved 2004, suspended 2005 after two deaths
What it is
NeutroSpec was a two-part radiopharmaceutical: fanolesomab, a mouse (murine) IgM monoclonal antibody, and technetium-99m, the radioactive atom used to see it. Each kit held 0.25 mg of lyophilized antibody with maltose, stannous tartrate, succinic acid, glycine and EDTA; a nuclear pharmacy dissolved it in sodium pertechnetate Tc 99m, held it at 37 °C for thirty minutes and injected the result intravenously. The antibody sticks to CD15, a carbohydrate marker on neutrophils, so the radiation follows white cells to sites of infection. American regulators approved it in July 2004 for unclear appendicitis; its makers suspended sales in December 2005.
What it does
Fanolesomab's practical selling point was that it labeled neutrophils inside the body. Standard infection imaging required drawing a patient's blood, separating leukocytes, tagging them with indium-111 oxine or technetium-99m HMPAO and reinfusing them — two hours of skilled laboratory work plus a biohazard exposure for staff. NeutroSpec replaced that with one intravenous injection and a planar gamma camera, and in half of the pivotal patients a diagnostic appendiceal image appeared within eight minutes. The scan reads as a blood-pool and reticuloendothelial study with urinary excretion: liver, spleen, marrow and kidneys are normally hot, and bowel activity creeps in over about four hours. A positive study is an irregular, asymmetric right-lower-quadrant focus that persists or brightens between 30 and 60 minutes. Its clinical job was narrow — to push a patient with equivocal appendicitis toward surgery or discharge without a night of observation or a negative appendectomy.
How it works
Fanolesomab's target is CD15, also called 3-fucosyl-N-acetyllactosamine or SSEA-1 — a fucose-bearing carbohydrate epitope on polymorphonuclear neutrophils, eosinophils and monocytes. The antibody is a mouse IgM, a pentamer whose several binding arms give it high avidity, and it holds CD15 with an apparent dissociation constant of 1.6 × 10⁻¹¹ M; one circulating neutrophil presents about 510,000 of those sites. Binding is non-signalling: labeled neutrophils keep their adhesion, phagocytosis and chemotaxis, which is exactly why they still travel into infected tissue. Uptake therefore runs on two routes. Antibody bound to circulating neutrophils rides with them as they marginate and migrate to the infection, and antibody also attaches to neutrophils and neutrophil debris already parked at the site. The technetium-99m in the kit — 6.02-hour half-life, a 140.5 keV gamma ray emitted in 89% of decays — supplies the signal a gamma camera records. One hour after injection, 72% of blood radioactivity sat in plasma and 25% on neutrophils; by two hours the liver held half the dose. The same neutrophil binding lay behind the toxicity: circulating counts dipped within minutes of injection, and the dangerous cardiopulmonary events were likewise immediate. No mechanism for them was ever established.
Step by step
- Antibody locks onto CD15 — The variable regions of the mouse IgM recognise 3-fucosyl-N-acetyllactosamine on neutrophils with a dissociation constant of 1.6 × 10⁻¹¹ M, and each neutrophil displays roughly 510,000 binding sites.
- Neutrophils become the radiolabel's carrier — Technetium-99m bound in the kit emits a 140.5 keV gamma ray; one hour after injection 25% of blood radioactivity sits on neutrophils and 72% in plasma.
- Labeled cells collect where neutrophils collect — Circulating labeled neutrophils migrate into infected tissue, and antibody also binds neutrophils and cell debris already sequestered there, so signal builds at the same address as the inflammation.
- A focal hot spot appears on planar images — An irregular, asymmetric right-lower-quadrant focus that persists or intensifies by 60 minutes is read as positive; 98% of true positives showed uptake by that point.
- Circulating neutrophil counts fall briefly — Counts dropped within 3 to 5 minutes of injection and returned to baseline within four hours, a downward shift recorded in 18% of patients.
What it is used for
- Equivocal signs and symptoms of appendicitis
- Osteomyelitis of the appendicular skeleton, including diabetic foot
- Prosthetic vascular graft infection
- Renal allograft infection and rejection
- Other intra-abdominal, postsurgical and soft-tissue infection
Dosing as the label states it
The label states a single intravenous adult dose of 75 to 125 micrograms of fanolesomab labelled with 10 to 20 mCi (370 to 740 MBq) of technetium-99m, given through a line confirmed patent and flushed with saline afterwards. Children five years and older receive 0.21 mCi/kg to a maximum of 20 mCi. Imaging follows: ten four-minute dynamic frames, then static views after the patient walks for 10 to 15 minutes and voids.
What to watch for
- Cardiopulmonary collapse — cardiac arrest, hypoxia, hypotension, dyspnea, sometimes within minutes of injection
- Flushing
- Dyspnea
- Transient neutropenia, with counts falling within 3 to 5 minutes and recovering by four hours
- Hypotension
- Chest pressure with falling oxygen saturation
- Human anti-mouse antibody response after a second injection
- Anaphylaxis or other serious hypersensitivity to mouse protein or to the sulfite in the diluent
Interactions
- Other mouse-derived antibodies (sulesomab, besilesomab, arcitumomab) — A shared murine protein backbone means antibody against one can cross-react with the next, and human anti-mouse antibody alters clearance and biodistribution of the later dose.
- Sulfite-containing medicines and the kit's own ascorbic acid diluent — The diluent carries sodium hydrosulfite, a sulfite that adds to any sulfite hypersensitivity and can precipitate bronchospasm or anaphylaxis.
- Myelosuppressive chemotherapy — The tracer's target is the neutrophil itself, so a depleted marrow removes the antigen sink the image depends on and shifts uptake toward liver and marrow.
- Granulocyte colony-stimulating factor — Mobilising and expanding the neutrophil pool multiplies available CD15 sites and increases marrow and splenic uptake, changing the normal scan pattern.
Avoid if
- Hypersensitivity to murine proteins or any kit component — the label's contraindication, because a mouse antibody can trigger anaphylaxis.
- Sulfite sensitivity — the ascorbic acid diluent contains sodium hydrosulfite, a sulfite capable of causing allergic reactions including anaphylaxis.
- Severe underlying cardiopulmonary disease — every serious post-marketing event arose in patients with this kind of compromise, treated for unapproved indications.
- Neutropenia — the target cell is scarce, and the label states safety and effectiveness in these patients were never established.
- Pregnancy — Category C, with no animal reproductive studies and no human data.
- A second dose weeks later — two injections induced human anti-mouse antibody in 5 of 30 volunteers.
How it was discovered
Fanolesomab started as RB-5, a mouse IgM raised against a carbohydrate antigen on human granulocytes and originally catalogued as anti-SSEA-1. The antibody came from the Wistar Institute and was developed by Palatin Technologies of Cranbury, New Jersey under the name LeuTech. Its appeal was affinity: 1.6 × 10⁻¹¹ M for CD15, with roughly 510,000 binding sites on each neutrophil, so the pentameric antibody held white cells firmly enough that a diagnostic image could be finished in about an hour, without drawing, separating and reinfusing the patient's own cells.
Approval history
Palatin filed a biologics license application and collected a complete-review letter from the FDA on 28 September 2000, then waited four more years while manufacturing and validation questions were settled. A Phase III programme of 203 patients at ten American sites supported the filing. The FDA cleared NeutroSpec on 6 July 2004 for scintigraphic imaging of equivocal appendicitis in patients aged five and older, with Mallinckrodt handling sales. On 19 December 2005, at the FDA's request, Palatin and Mallinckrodt suspended sales and recalled inventory. The database record still carries a withdrawn flag, the label stayed posted into 2007, and the product was discontinued in 2008.
Impact
Roughly 11,000 patients were imaged before the recall. The FDA counted 17 serious post-marketing cardiopulmonary events and two deaths, all in patients who did not have suspected appendicitis; 15 recovered, three of them in intensive care and two after resuscitation. A 2007 paired study showed how far the ground had shifted — FDG-PET/CT found infection with 100% sensitivity in 12 patients where fanolesomab found 30%. Fanolesomab never returned to the American market, and reviews of the field cite the episode when arguing for humanised antibodies over mouse ones.
What the research shows
Efficacy rests on single-arm, open-label studies; safety was rebuilt afterwards from post-marketing reports, and no randomised comparison with another imaging strategy exists.
Key findings
- Blinded readers scored the pivotal scan at 75% sensitivity and 93% specificity for appendicitis, while investigators with clinical access scored 91% and 86%.
- Against histopathology in the same 200 patients, sensitivity was 90%, specificity 87% and negative predictive value 95%, and half of diagnostic images were obtained within 8 minutes of injection.
- Fanolesomab identified infection in 30% of paired studies where FDG-PET/CT identified 100%, a significant gap in both sensitivity and accuracy.
- Safety before approval rested on 523 exposed subjects, among whom 49 adverse events occurred in 37 people (7%), four of them severe.
- Post-marketing surveillance turned up 17 serious cardiopulmonary events and 2 deaths among roughly 11,000 treated patients, none in the approved indication.
What is still unsettled
No randomised trial ever pitted fanolesomab against CT, ultrasound or admission for observation, and the pivotal studies were single-arm with a 30% disease prevalence, which inflates predictive values. The biological cause of the cardiopulmonary reactions was never identified — complement activation by a pentameric mouse IgM, with pulmonary leukoagglutination, is a plausible but untested explanation. The FDA concluded that post-approval data could not identify which patients were at higher risk, and the drug was never studied in neutropenic patients, in pregnancy, or in repeat dosing.
Open questions
- What made a pentameric mouse IgM drop blood pressure and oxygen saturation within minutes in some patients but not in the 523 studied before approval?
- Both patients who died were diabetic — coincidence, or a signal of underlying vascular and cardiac disease?
- Would a smaller Fab' fragment or a humanised anti-CD15 antibody have kept the one-hour image without the cardiopulmonary risk?
- Has any neutrophil-specific tracer closed the gap with FDG-PET/CT, or did the 2007 comparison settle the question?
More in this index
- Technetium (99mTc) nofetumomab merpentan
- Technetium (99mTc) pintumomab
- Technetium (99mTc) sulesomab
- Technetium (99mTc) tilmanocept
- Technetium (99mTc) votumumab
- Teclozan
Sources
- NeutroSpec (technetium Tc 99m fanolesomab) prescribing information, Mallinckrodt
- Rypins et al., anti-CD15 (LeuTech) imaging in equivocal appendicitis, Annals of Surgery 2002
- Klingensmith et al., FDG-PET/CT versus Tc-99m fanolesomab for infection, 2007
- Clinical translation of neutrophil imaging, 2022 review (CD15 target, affinity, suspension)
- ChEMBL record CHEMBL2107902 — technetium Tc 99m fanolesomab, antibody, first approval 2004, withdrawn
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.