Medicine
Technetium (99mTc) votumumab
A human antibody scan for colorectal cancer, approved in Europe in 1998 and gone by 2003
What it is
Technetium (99mTc) votumumab is a diagnostic radiopharmaceutical: a fully human IgG3κ monoclonal antibody, clone 88BV59, labelled with technetium-99m and injected into a vein. It carries no drug payload and treats nothing. The antibody binds an antigen displayed in colorectal tumour tissue, and the isotope's gamma rays are captured with a gamma camera or SPECT to map where tumour deposits sit. Its brand name was HumaSPECT, authorised across the European Union on 25 September 1998 as an adjunct to ultrasound or CT, and never marketed anywhere.
What it does
Once injected, the antibody circulates for hours and accumulates wherever its antigen is displayed in tumour tissue, while unbound molecules are slowly cleared. Because an intact IgG3 antibody leaves the blood slowly, images are acquired 14 to 20 hours after the injection, when tumour signal has had time to rise above blood-pool background. Planar gamma-camera views and tomographic SPECT slices then show the distribution of the isotope through the abdomen and pelvis. In practice the scan was read next to computed tomography and ultrasound, not instead of them: the authorised use was as an adjunct for judging the extent of recurrence or metastases and whether disease could be resected. Its contribution was greatest for extrahepatic abdominal and pelvic deposits; CT remained better for liver metastases and for anatomical detail.
How it works
Votumumab binds CTA 16.88, a tumour-associated determinant homologous to cytokeratins 8, 18 and 19 — intermediate-filament proteins of epithelial cells — carried by most epithelial-derived carcinomas, among them colorectal, pancreatic, breast, ovarian and lung tumours. The antibody is a fully human IgG3κ (clone 88BV59), so its constant regions are human and repeated exposure provoked almost no anti-antibody response. Binding is non-signalling: no enzyme is inhibited and no receptor is blocked. The antibody is only a carrier whose job is to hold the isotope where the antigen is, and retention is greatest in non-necrotic tumour tissue. Tumour-to-background contrast depends on how much antibody arrives, how much sticks and how fast the remainder leaves the blood — hence imaging 14 to 20 hours after injection. Cytokeratins are intracellular filaments, so how much antigen a circulating antibody can actually reach in tumour tissue is itself the step that decides whether a deposit appears. Technetium-99m, attached to the protein, decays by isomeric transition with a 6.02-hour physical half-life, and its 140 keV gamma rays escape the body to be located by a gamma camera or SPECT. The signal reports antigen density and accessibility, not cell killing.
Step by step
- Antibody meets antigen — The IgG3κ binds CTA 16.88, a cytokeratin-8/18/19-related determinant carried by epithelial-derived tumour tissue.
- Retention in tumour — Bound antibody stays in non-necrotic tumour areas while unbound intact IgG3 clears slowly from the bloodstream.
- Contrast develops — Waiting 14 to 20 hours lets tumour activity rise above the residual blood-pool background.
- Isotope emits — Technetium-99m decays by isomeric transition, half-life 6.02 hours, releasing 140 keV gamma rays.
- Camera localises — A gamma camera or SPECT reconstructs where the isotope sits; there is no pharmacological effect on the tumour.
What it is used for
- Imaging of recurrence and/or metastases in histologically proven carcinoma of the colon or rectum, as an adjunct to ultrasound or CT while extent of disease is assessed before surgery or other therapy
- Suspected recurrence or metastases with rising serum carcinoembryonic antigen and a negative or equivocal CT scan
- Pre-surgical prediction of whether disease is resectable
- Operative gamma-probe scintimetry of tumour beds and resection margins during colorectal surgery
- Detection of primary, not just recurrent, colorectal cancer
What to watch for
- Human anti-human antibody (HAHA) response
- False-positive scan suggesting tumour where surgery found none
- Understaging of disease extent
- Overstaging of disease extent
- Missed liver metastases
- Infusion reaction to the antibody
- Whole-body radiation dose from the technetium-99m label
Interactions
- Another technetium-99m radiopharmaceutical given in the same session — Both emit the same 140 keV gamma, so the two distributions superimpose on the scan and cannot be separated by the camera
- Earlier imaging with mouse (murine) antibodies, which leaves human anti-mouse antibodies in the blood — Circulating anti-mouse antibody binds the injected antibody into immune complexes cleared by liver and spleen, shifting the biodistribution; in the reviewed series high anti-mouse titres did not prevent imaging
- Cytotoxic chemotherapy that shrinks or necroses tumour between injection and imaging — Retention depends on accessible antigen in non-necrotic tumour tissue, so antigen loss lowers the tumour signal and can make a real deposit look negative
- Immunosuppressive treatment — A blunted antibody response could reduce HAHA formation after dosing, but no study of votumumab measured this
Avoid if
- Pregnancy — technetium-99m delivers gamma radiation to the fetus, and no pregnancy data were ever published for this product.
- Breastfeeding — excretion of this antibody into milk was never measured, and the product information that would have set a precaution has been withdrawn.
- Colorectal cancer not confirmed histologically — the authorised indication was restricted to histologically proven carcinoma of the colon or rectum.
- Known hypersensitivity to the antibody or its formulation — any intravenous protein can provoke a reaction on re-exposure, and the full excipient list is no longer published.
How it was discovered
Votumumab came out of the 1980s push to replace mouse antibodies, which provoked human anti-mouse responses that blocked repeat imaging. The starting material was B cells from cancer patients actively immunised with their own tumour antigen. Clone C088BV59 was fused with a human-mouse heteromyeloma to make C088BV59H21-2, then re-exposed to Epstein-Barr virus to yield C088BV59H21-2V67-66, a line that passaged better in culture and produced three to five times more antibody. The product was a fully human IgG3κ recognising CTA 16.88, a determinant related to cytokeratins 8, 18 and 19.
Approval history
The European Commission granted a marketing authorisation for HumaSPECT (votumumab) on 25 September 1998 to Organon Teknika, later transferred to KS Biomedix Ltd, for imaging recurrence and metastases of histologically proven colon or rectal carcinoma as an adjunct to ultrasound or CT. The product was never marketed anywhere in the world. On 22 September 2003 KS Biomedix told the Commission it would not renew the authorisation for commercial reasons, noting that other radiopharmaceuticals covered the indication; the authorisation expired on 24 September 2003 and the European public assessment report was removed.
Impact
HumaSPECT arrived at the high point of radioimmunoscintigraphy and left as the field was being overtaken. Its phase III programme of 202 assessable patients showed an antibody scan could beat CT on specificity and on predicting resectability, and that a fully human antibody raised almost no anti-antibody response — 2 of 53 patients, low titre. But an intact IgG3 clears slowly, so images waited a day and stayed grainy beside anatomical scans. When KS Biomedix declined to renew in 2003 it cited commercial reasons and pointed to other radiopharmaceuticals already serving the indication; no trial of votumumab is registered anywhere.
What the research shows
One pivotal phase III programme published in 1998, plus single-centre pilot series from 1993 to 1997. No randomised controlled trial, no systematic review, no registered study in ClinicalTrials.gov, and no trial since the product lapsed in 2003.
Key findings
- Sensitivity 87% in patients whose CT already showed tumour, with specificity 57% against 17% for CT (P<.001)
- Accuracy for identifying resectable versus non-resectable disease was 80% against 62% for CT; understaging 27% versus 41% and overstaging 4% versus 26%
- More accurate than CT at determining resectability in 170 evaluable patients with recurrent or metastatic disease, and also in the occult-disease group
- SPECT sensitivity 78% against 43% for CT across 23 histologically proven tumour sites; operative gamma probe reached 91%
- The antibody scan found about 25% more lesions than CT, with 68% against 41% sensitivity for extrahepatic disease; none of the 24 patients mounted a HAHA response
What is still unsettled
Every comparison is against CT read by the same team, without randomisation or blinding and without a patient-outcome endpoint, so no study shows that acting on the extra lesions changed survival. Why an antibody against a cytokeratin-related intracellular determinant concentrates in tumour tissue at all is still not explained. And because the product information was withdrawn with the authorisation, dose, excipients and contraindications can no longer be checked against a label.
Open questions
- Does adding an antibody scan to modern anatomical and metabolic imaging change surgical decisions or survival, rather than merely improving staging accuracy?
- How does a circulating antibody reach a cytokeratin-8/18/19-related determinant that sits inside epithelial cells?
- Would the very low immunogenicity of a fully human IgG3 have made repeat dosing or antibody-directed therapy viable if the programme had continued?
- Which patients gained most — those with occult disease and rising CEA, or those with known but borderline resectable disease?
More in this index
Sources
- European Medicines Agency — HumaSPECT (votumumab), withdrawn medicine page
- Serafini et al., Journal of Clinical Oncology 1998 — pivotal phase III radioimmunoscintigraphy results
- Wolff et al., Diseases of the Colon & Rectum 1998 — resectability and patient-management benefit, 219 patients
- Moffat et al., Journal of Nuclear Medicine 1995 — 99mTc-88BV59 pilot with operative probe scintimetry
- Krause et al., European Journal of Nuclear Medicine 1997 — 24-patient series and immunogenicity assessment
- De Jager et al., Seminars in Nuclear Medicine 1993 — antigen CTA 16.88, IgG3κ isotype, HAHA frequency
- DailyMed — Technetium Tc 99m Sestamibi Injection label, physical characteristics of technetium-99m
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.