Medicine
Technetium (99mTc) tilmanocept
Technetium (99mTc) tilmanocept: a sugar-tagged tracer that finds a tumour's first lymph node
What it is
Technetium (99mTc) tilmanocept, sold as Lymphoseek, is a radioactive tracer injected beside a tumour so a surgical team can find the first lymph node draining that area, the node most likely to hold spreading cancer cells. It is diagnostic only: the radiation marks tissue, it does not treat it. A hospital pharmacy attaches technetium-99m, a gamma emitter with a six-hour half-life, to a mannose-coated dextran powder supplied as a kit. A hand-held probe then turns the node's radioactivity into clicks the surgeon can follow.
What it does
In theatre the drug works as a surgical tool rather than a scan. A nuclear pharmacy radiolabels the kit, and the team injects it intradermally, subcutaneously, subareolar or around the tumour at least 15 minutes before mapping; a lymphoscintigram may be taken first to show where drainage runs. The surgeon then sweeps a gamma probe across the basin and removes nodes counting well above background, usually with blue dye and palpation as a second and third check. Nodes are judged against background counts, and the hottest ones are taken first; excised tissue goes to pathology, where step sections and cytokeratin stains set the stage. Because the tracer stays bound in nodes for many hours, injection can happen the day before surgery when lists and radiopharmacy hours do not line up.
How it works
The target is CD206, the mannose receptor, a lectin displayed on macrophages and dendritic cells that populate lymph nodes. Tilmanocept is a dextran backbone of roughly 10 kDa carrying 12-20 mannose sugars and 3-8 DTPA chelators: the sugars are the address, the DTPA grips the technetium-99m atom. Mannose binds CD206 with a dissociation constant near 2.8 x 10^-11 M, so the molecule is held by cells rather than sieved out of lymph. That is the design idea. Colloid particles lodge because they are too big to pass; tilmanocept is small, about 7 nm in the first synthesis, slips into lymphatic capillaries within minutes, then sticks where CD206 is dense. Injected beside a tumour it reaches the draining node inside 10 minutes and stays detectable for up to 30 hours, while unbound tracer leaves the injection site with a half-life of roughly 2-3 hours. Technetium-99m emits a 140 keV gamma ray that crosses tissue, and the probe converts those counts into clicks. Only about 1-2% of the dose lands in each of liver, kidney and bladder at peak, an hour after injection. Nothing in the molecule kills cells.
Step by step
- Inject beside the tumour — A small volume goes intradermally, subcutaneously, subareolar or peritumoral, and the mannose-decorated molecules enter lymphatic capillaries within minutes.
- Ride the lymph to the first node — Tracer reaches the draining sentinel node inside 10 minutes, faster than the larger colloid particles used since the 1970s.
- Bind CD206 and stay — Mannose residues lock onto mannose receptors on nodal macrophages and dendritic cells, so counts in the node stay high while background clears.
- Turn radioactivity into clicks — The 140 keV gamma rays from technetium-99m reach a hand-held probe, which reports count rates the surgeon can hear and read.
- Cut, then check — The hottest node is excised and examined histologically; a negative node is confirmed with step sections and cytokeratin staining.
What it is used for
- Sentinel node biopsy in breast cancer
- Sentinel node biopsy in melanoma
- Clinically node-negative squamous cell carcinoma of the oral cavity
- Lymphatic mapping in other solid tumours where mapping guides intraoperative management
- Solid tumours in children from one month of age
Dosing as the label states it
The label states a single dose of 18.5 MBq (0.5 mCi) carrying 50 mcg of tilmanocept, injected at least 15 minutes before lymphatic mapping, with the procedure completed within 15 hours of injection.
What to watch for
- Irritation at the injection site
- Pain at the injection site
- Allergic reaction: rash, hives, wheeze or falling blood pressure, a concern because the dextran backbone resembles dextran medicines that have caused serious reactions
- No sentinel node identified at all, leaving the surgeon to rely on blue dye and palpation
- A cancerous node read as negative, the failure that matters most because it can under-stage the cancer
- Long-term radiation-related cancer risk, which weighs more heavily in children than in adults
Interactions
- Local anaesthetics injected near the tumour — The label notes that locally injected anaesthetics reduce lymphatic flow in animal studies, so tracer migration to the node can stall and mapping fails; concomitant use is not recommended.
- Other technetium-99m radiopharmaceuticals given the same day — All emit the same 140 keV gamma peak, and a gamma probe cannot separate one from another, so the counts over a node become a mixture of two studies.
- Earlier lymphoscintigraphy with sulphur colloid in the same basin — Colloid left in nodes from a previous injection keeps emitting, and the pattern of hot spots no longer maps cleanly onto the new injection.
- Dextran-containing medicines, especially iron dextran — The dextran backbone shares structural features with dextran drugs that have caused serious hypersensitivity, so pre-formed antibodies could react to the tracer.
- Previous surgery, radiotherapy, oedema or inflammation in the drainage area — Scarring and swelling reroute or block lymph channels, so the tracer may bypass the true sentinel node or pool where no node sits.
- Cancer that has largely replaced a node — Tumour crowds out the macrophages and dendritic cells that carry CD206, so the node that most needs finding may hold little tracer.
Avoid if
- A previous serious reaction to dextran or to an iron dextran product, which the label asks about before any injection
- Pregnancy, unless the information from the procedure is judged worth the radiation dose to the fetus
- Breastfeeding in the first 24 hours, when the label advises expressing and discarding milk
- A child younger than one month, the lower age limit of the approved paediatric indication
- An injection site in a biopsy wound that is swollen or inflamed
How it was discovered
David R. Vera and colleagues at the University of California, San Diego, with Anne Wallace, Carl Hoh and Robert Mattrey, published the molecule in the Journal of Nuclear Medicine in 2001 as 99mTc-DTPA-mannosyl-dextran. Their rabbit experiments set the template: a 7.1 nm dextran carrying 8 DTPA chelators and 55 mannose residues extracted 90-98% of the dose in the popliteal node, against 67-79% for filtered sulphur colloid. The point was to make retention a receptor event rather than a size filter.
Approval history
The Ohio radiopharmaceutical company Neoprobe, renamed Navidea Biopharmaceuticals in January 2012, took the molecule through two open-label phase 3 trials in breast cancer and melanoma. The FDA approved NDA 202207 on 13 March 2013 under standard review with orphan designation. Oral cavity squamous carcinoma was added in June 2014, European authorisation came on 19 November 2014, and a paediatric indication from one month of age followed on 19 May 2021.
Impact
Tilmanocept was the first sentinel node agent approved in the United States on a receptor-binding rationale rather than particle trapping, and the first new one in decades. Navidea sold the US, Canadian and Mexican rights to Cardinal Health 414 on 3 March 2017 under an agreement dated 23 November 2016. The European marketing authorisation was withdrawn on 10 June 2024 at Navidea's European arm's request for commercial reasons, not safety. Vera's group has since attached fluorescent dyes to the same backbone for fluorescence-guided surgery.
What the research shows
Approved and in routine surgical use for breast cancer, melanoma and oral cavity cancer, but the comparative evidence against older sulphur colloid remains small, single-arm or retrospective, and no large randomised trial has shown that better node detection changes recurrence or survival.
Key findings
- In 148 women with breast cancer having both agents, tilmanocept identified 320 nodes to blue dye's 207, found at least one node in 146 patients against 131, and located 31 of 33 cancerous nodes against 25 of 33.
- Among 101 patients with head and neck squamous carcinoma and planned neck dissection, a sentinel node was found in 97.6%, the false-negative rate was 2.56%, negative predictive value 97.8% and overall accuracy 98.8%.
- Across 324 head and neck melanoma patients, radiotracer migration failure was 1.9% with tilmanocept versus 11.5% with sulphur colloid, though 5-year recurrence differences were not statistically significant.
- A 23-patient single-arm trial in children aged 1.7 to 17 years found no safety or localisation differences from adults, which supported the 2021 label expansion.
What is still unsettled
The strongest head-to-head comparison is a retrospective series from one institution, so the size of any real advantage over colloid is unresolved. Whether the extra nodes found translate into fewer missed metastases clinically is inferred from detection statistics rather than outcome trials, and long-term radiation risk in children is estimated from dosimetry rather than observed.
Open questions
- Does finding more nodes with a CD206-targeted tracer reduce recurrence or improve survival compared with sulphur colloid in a randomised trial?
- Can the same mannose-receptor signal be used to image tumour-associated macrophages and predict who responds to immunotherapy?
- Why did the European commercial case fail in 2024 while US use continued, and what does that mean for access outside the United States?
- What injection timing and dose are best in children and in head and neck cancer, where drainage anatomy is least forgiving?
More in this index
Sources
- US prescribing information, Lymphoseek (technetium Tc 99m tilmanocept) injection, revised May 2021
- Drugs@FDA, NDA 202207 approval history and supplements
- European Medicines Agency, Lymphoseek (withdrawn 10 June 2024)
- Vera DR et al., A synthetic macromolecule for sentinel node detection: 99mTc-DTPA-mannosyl-dextran, J Nucl Med 2001
- Wallace AM et al., Comparative evaluation of 99mTc-tilmanocept in breast cancer: two phase 3 trials, Ann Surg Oncol 2013
- Agrawal A et al., 99mTc-tilmanocept in oral squamous cell carcinoma: phase III trial, Ann Surg Oncol 2015
- Maddineni S et al., Tilmanocept versus sulphur colloid in head and neck melanoma, Ann Otol Rhinol Laryngol 2025
- Wikipedia, Technetium (99mTc) tilmanocept
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.