Medicine
Technetium (99mTc) pintumomab
A technetium-99m-labelled mouse antibody that imaged ovarian cancer but was never approved
What it is
Technetium (99mTc) pintumomab is the international nonproprietary name for 170H.82, a mouse monoclonal antibody raised against the Thomsen-Friedenreich (TF) sugar antigen and radiolabelled with technetium-99m. Biomira, of Edmonton, Canada, developed it as Tru-Scint AD, an imaging kit a nuclear medicine department could label with pertechnetate and inject before a gamma-camera scan. It was never licensed: the Canadian submission was withdrawn in 1997 and no product reached the US market. The name covers antibody plus radioisotope together, and it has no ATC code.
What it does
It was built as a diagnostic, not a treatment: the antibody is the homing device and the technetium is the beacon. An injected dose circulates as intact immunoglobulin, and where TF antigen is displayed on tumour mucin the antibody sticks; unbound antibody leaves the blood pool and is excreted, so tumour-bound radioactivity stands out on planar and SPECT images taken from about fifteen minutes to twenty-four hours after injection. The intended jobs were preoperative questions, such as whether an ovarian mass was malignant or whether breast cancer had reached the axilla, in cases where computed tomography and ultrasound were equivocal. Because the isotope emits gamma rays rather than killing cells, the agent produced pictures, not therapeutic effects. Later work attached therapeutic isotopes, yttrium-90 and rhenium-186, to the same antibody for high-dose radioimmunotherapy.
How it works
The target is the Thomsen-Friedenreich antigen, a core-1 disaccharide (Gal beta1-3GalNAc alpha1-O-Ser/Thr) carried on the O-glycans of epithelial mucins. In healthy colon mucin the structure is capped by sialic acid and fucose and stays hidden: direct measurement found 1.5 micrograms of releasable TF per milligram of protein in normal mucosa against 8.0 in adenocarcinoma, and mild acid treatment raised the normal figure to 5.5, showing the epitope was masked rather than absent. 170H.82 is a murine IgG1 raised against a synthetic TF glycoconjugate, and roughly 90 per cent of human carcinomas display TF, which is why it behaved as a pan-adenocarcinoma antibody. Binding is bivalent and the immune complex persists on tumour cells and in tumour mucin, so radioactivity accumulates where antigen is dense. Technetium is attached directly: reducing interchain disulfides, or photoactivating them with ultraviolet light, frees thiols that bind pertechnetate without a separate chelator, and dithionite reduction reached about 90 per cent monomeric labelling efficiency. Decay of technetium-99m, half-life 6.1 hours with 140 keV gamma rays at about 90 per cent abundance, is then read by a gamma camera. Blood clearance sets the contrast: distribution half-life 4.0 hours, elimination 39.6 hours, 12 per cent of activity in urine by 24 hours, and the kidney as the critical organ at 37 mGy per gigabecquerel.
Step by step
- Radioisotope is bolted on — Interchain disulfides are reduced or photoactivated to free thiols that bind pertechnetate directly, giving about 90 per cent monomeric labelling without a chelator.
- Antibody finds the TF sugar — The bivalent murine IgG1 binds Gal beta1-3GalNAc alpha on tumour mucins; the same structure is capped by sialic acid and fucose in normal mucosa.
- Activity parks at the tumour — Bound antibody stays put while unbound IgG clears with a 39.6-hour elimination half-life, leaving tumour-to-background contrast.
- Six-hour decay lights the image — Technetium-99m emits 140 keV gamma rays that a gamma camera or SPECT detector maps; the kidneys absorb the highest normal dose.
What it is used for
- Preoperative imaging of ovarian adenocarcinoma
- Primary and recurrent breast adenocarcinoma
- Axillary lymph node assessment in breast cancer
- Triage of complex pelvic masses
- Intraperitoneal dosimetry before rhenium-186 radioimmunotherapy
- Yttrium-90 radioimmunotherapy of metastatic breast cancer
What to watch for
- Human anti-mouse antibody response
- False-positive scan in benign pelvic disease
- Kidney radiation exposure
- Red marrow radiation dose after intraperitoneal administration
- Hypersensitivity to mouse immunoglobulin
Interactions
- Pre-existing human anti-mouse antibodies from earlier murine antibody exposure — HAMA binds the mouse IgG1 in plasma, forming immune complexes that accelerate clearance and lower tumour uptake, while adding a hypersensitivity risk.
- Other technetium-99m radiopharmaceuticals given the same day — They share the same 140 keV photopeak, so camera counting cannot separate the two contributions, and the radiation dose is additive.
- External beam radiotherapy or other marrow-directed irradiation — Marrow dose from a radiolabelled antibody adds to dose from other radiation sources; this mattered for the yttrium-90 therapy version.
- Large amounts of shed mucin antigen in the bloodstream — Circulating antigen acts as a sink, binding antibody before it reaches tumour and shortening its residence time; a comparator technetium antibody in the same analysis cleared faster for this reason.
Avoid if
- Pregnancy: the scan delivers ionizing radiation to the fetus, and no human pregnancy data were published.
- Breastfeeding: nothing was published on excretion of this antibody in milk, so infant radiation exposure cannot be excluded.
- Previous severe reaction to mouse-derived antibodies: the antibody is a whole murine IgG1, and pre-existing HAMA both degrades image quality and raises reaction risk.
How it was discovered
170H.82 came out of a Biomira programme in Edmonton that raised mouse antibodies against synthetic tumour-associated carbohydrates rather than purified tumour tissue. The antibody, directed at the TF disaccharide, was reported in 1992 with both indium-111 and technetium-99m labelling and pilot imaging in 48 patients with a range of adenocarcinomas, at 92 per cent overall accuracy. The company's argument was economic as much as biological: a technetium label cost about two dollars against four hundred or more for indium, and a generator-produced isotope fitted an ordinary nuclear medicine department without a cyclotron.
Approval history
Pintumomab was assigned as an international nonproprietary name and entered the WHO-derived INN lists reproduced in EU tariff annexes with CAS number 157476-76-1. Biomira filed a Canadian new drug submission for Tru-Scint AD in 1996, covering recurrent breast cancer and primary, residual or recurrent ovarian cancer. In December 1997 the company withdrew it after the regulator said the data were insufficient. No FDA application was approved, and the agent appears in none of the agency's drug, label or NDC databases; no European authorisation followed either.
Impact
The agent is a footnote, but an instructive one. It showed that a six-hour technetium label could produce same-day radioimmunoscintigraphy of ovarian and breast cancer at a time when indium-111 antibodies demanded days between injection and imaging. Its weakness was specificity: an anti-TF antibody sticks to inflamed and benign tissue as readily as to tumour, and in one series six of nine benign pelvic masses scanned positive. The same antibody was later pushed toward therapy with yttrium-90 and rhenium-186, and anti-TF targeting continues in other laboratories, but pintumomab itself never carried a marketed product.
What the research shows
A handful of single-centre prospective imaging series from 1992 to 2001, with no randomised trial, no approved product, and no registration on ClinicalTrials.gov.
Key findings
- Ovarian cancer detection reached 88 per cent sensitivity and 90 per cent specificity, with 92 of 110 known lesions visualised.
- Per-lesion sensitivity was 83.5 per cent and positive predictive value 97.7 per cent across three protein dose levels, best for breast and locoregional disease.
- Specificity collapsed to 33 per cent when benign pelvic pathology was present, with 6 of 9 benign cases read as positive.
- Only 2 of 23 patients (9 per cent) developed HAMA six weeks after a 2 mg dose, and no adverse effects were observed.
- Intraperitoneal delivery was dosimetrically compatible with rhenium-186 therapy at activities up to 3.7 GBq.
What is still unsettled
Everything rests on small single-centre series with no blinded comparison against CA125, computed tomography or surgical staging. The largest ovarian reports come from one German group and the breast data from Edmonton, so reproducibility outside those centres is unknown. Whether the antibody's affinity for TF was ever high enough to separate tumour from inflammation was never settled, and the regulatory file that might have answered it was withdrawn and never published.
Open questions
- Does anti-TF immunoscintigraphy add diagnostic information over CA125 plus transvaginal ultrasound and CT in a randomised setting?
- Which mucin backbones carry the exposed TF epitope in vivo, and does the amount of shed antigen in plasma predict who images well?
- Would a smaller fragment or a humanised anti-TF antibody raise tumour-to-background enough to fix the false-positive problem in benign pelvic disease?
- Can the same antibody deliver rhenium-186 or yttrium-90 at activities that control tumour without exceeding marrow tolerance?
More in this index
- Technetium (99mTc) sulesomab
- Technetium (99mTc) tilmanocept
- Technetium (99mTc) votumumab
- Teclozan
- Tedisamil
- Tedral
Sources
- EU Combined Nomenclature, Annex 3: list of INNs (technetium (99mTc) pintumomab, CAS 157476-76-1)
- Campbell et al., J Clin Invest 1995: TF antigen is exposed in colonic adenocarcinoma and concealed in normal mucin
- Current Radiopharmaceuticals review: technetium-99m half-life 6.1 h, 140 keV gamma emission
- Alexander et al., Am J Obstet Gynecol 1999: MAb-170 immunoscintigraphy in 82 women with ovarian tumours
- Lieberman et al., Am J Obstet Gynecol 2000: preoperative diagnosis of ovarian carcinoma, specificity 33 per cent
- McQuarrie et al., Eur J Nucl Med 1997: phase II radioimmunoscintigraphy in 53 women with breast adenocarcinoma
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.