Medicine
Technetium (99mTc) albumin aggregated
Albumin particles 10–90 µm wide that lodge in lung capillaries to map blood flow
What it is
Technetium (99mTc) albumin aggregated is a radioactive diagnostic agent, not a treatment. A vial holds human albumin that has been heat-denatured into fragile microscopic clumps and sealed with stannous chloride; minutes before use it is mixed with sodium pertechnetate Tc-99m, which binds to the protein. The finished suspension is injected into a vein. Particle size is the design specification: at least 90% measure 10 to 90 micrometers and none exceed 150. Two US kits, PulmoTech MAA and DraxImage MAA, supply it, each with 2 mg to 2.5 mg of aggregated albumin and millions of particles.
What it does
After labeling, the dose is injected slowly into a vein while the patient already lies under a gamma camera, because extraction by the lung is almost immediate. Adults typically receive about 350,000 particles, within a permitted range of 200,000 to 700,000, and those particles distribute in proportion to regional pulmonary blood flow. A lung segment whose artery is blocked — by a clot in acute pulmonary embolism, or by organized fibrous tissue in chronic thromboembolic disease — receives few particles and shows as a defect. Perfusion images are read alongside a ventilation scan: a perfusion defect with preserved ventilation points to vascular obstruction, while matched defects suggest airway or parenchymal disease such as COPD. The same suspension can be instilled into the peritoneal cavity to follow a peritoneovenous shunt.
How it works
This agent has no receptor, enzyme or transporter target; its target is anatomy. Albumin is heat-denatured with stannous chloride into fragile aggregates, and stannous ion reduces pertechnetate so technetium-99m is held on the protein. Size does the work. Pulmonary capillaries average roughly 5.5 micrometers across, aggregates above 10 to 15 micrometers cannot negotiate them, and the specification requires at least 90% of particles between 10 and 90 micrometers with none above 150. Within 1 to 5 minutes of intravenous injection, more than 90% are trapped in pulmonary arterioles and capillaries on first pass, distributed according to regional blood flow. The blockade is temporary: particles erode and fragment, shrink below the capillary threshold, re-enter the circulation and are cleared by the reticuloendothelial system, with a lung biological half-life of 10.8 hours (range 6.9 to 19, n=5). Technetium-99m decays by isomeric transition with a 6.02-hour physical half-life, emitting a 140.5 keV gamma ray. Aggregates under 10 micrometers bypass the lung and are taken up by liver, spleen and marrow, which is why extrapulmonary uptake signals a right-to-left shunt.
Step by step
- Particle manufacture — Heat denaturation of albumin human with stannous chloride creates fragile aggregates; at least 90% measure 10 to 90 micrometers and none exceed 150.
- First-pass trapping — More than 90% of injected particles lodge in pulmonary arterioles and capillaries within 1 to 5 minutes, because capillaries average about 5.5 micrometers.
- Flow-weighted distribution — Particles reach only regions that receive blood, so an obstructed artery leaves an unlabeled defect on the image.
- Fragmentation and clearance — Particles erode and shrink, pass the capillary bed and are removed by the reticuloendothelial system; lung biological half-life is 10.8 hours.
- Gamma emission — Technetium-99m decays with a 6.02-hour half-life and emits a 140.5 keV photon that the gamma camera detects.
What it is used for
- Lung perfusion scintigraphy in adults and children
- Peritoneovenous shunt patency
- Screening for chronic thromboembolic pulmonary hypertension
- Quantifying intrapulmonary shunt in hepatopulmonary syndrome
- Lung shunt fraction before yttrium-90 radioembolization
- Functional lung avoidance in radiotherapy planning
Dosing as the label states it
The label states that adults having lung perfusion scintigraphy receive 37 MBq to 148 MBq (1 mCi to 4 mCi) with 200,000 to 700,000 particles, typically about 350,000. Children aged 4 weeks and older receive 0.925 to 1.85 MBq/kg, minimum 7.4 MBq; neonates receive 7.4 to 18.5 MBq with 10,000 to 50,000 particles. For peritoneovenous shunt scintigraphy the label states 37 MBq to 111 MBq (1 mCi to 3 mCi) with 200,000 to 700,000 particles, given intraperitoneally.
What to watch for
- Death in severe pulmonary hypertension
- Anaphylaxis and other serious hypersensitivity reactions
- Wheezing, chest tightness or nausea shortly after injection, reported in a small proportion of patients
- Flushing, urticaria and sweating
- Injection site reaction
- Temporary mechanical obstruction of systemic blood flow when particles bypass the lung in a right-to-left shunt
- Added lifetime cumulative radiation exposure from a 6.02-hour technetium-99m source
Interactions
- Other technetium-99m particulate agents or a repeat MAA injection — Additive mechanical load on the same pulmonary capillary bed; particle number, not radioactivity, is the quantity that occludes vessels.
- Human albumin infusions and plasma-derived albumin products — Shared antigen, albumin human: earlier exposure could add to the risk of a hypersensitivity reaction to the particle.
- Pulmonary vasodilators such as inhaled nitric oxide or epoprostenol — They redistribute pulmonary blood flow, so the perfusion pattern reflects the drug effect alongside any obstruction.
- Anticoagulants and antiplatelet drugs — No shared enzyme or transporter and no labeled pharmacokinetic interaction; any added risk is bleeding at the venepuncture site.
Avoid if
- Severe pulmonary hypertension — deaths have been reported after albumin aggregate injection, and the label contraindicates its use.
- Previous hypersensitivity to human albumin, including reactions to albumin-containing products — anaphylaxis has occurred.
- A right-to-left cardiac shunt without reducing the particle number — aggregates can reach the systemic circulation and transiently obstruct blood flow.
How it was discovered
Lung perfusion imaging with particles began with George Taplin and colleagues at UCLA. A 1963 laboratory report and a 1964 Journal of Nuclear Medicine paper described suspensions of radioalbumin aggregates that could photoscan the liver, spleen, lung and other organs; lung uptake, a problem for liver imaging, turned out to map pulmonary blood flow. Albumin was already a well-understood plasma protein, and heat denaturation in the presence of stannous chloride produced aggregates that could later be labeled with technetium-99m eluted from a generator.
Approval history
Technetium Tc 99m albumin aggregated has been in routine lung perfusion scintigraphy since the early 1970s and remains the standard agent for it. The DraxImage kit label gives an initial US approval date of 1987; PulmoTech MAA, manufactured by CIS bio International and distributed by Curium, carries a 2020 approval with a modern label specifying pediatric particle tables, age-specific dosimetry and an 18-hour shelf life after labeling. Both products are kits rather than finished drugs: the nuclear pharmacy adds sodium pertechnetate Tc-99m, then assays activity, volume and particle count in a dose calibrator.
Impact
PIOPED fixed the scan's reputation and its limits: among 933 of 1493 patients studied prospectively, a high-probability scan was right 88% of the time, yet only 41% of patients with embolism had one, and any abnormality was 98% sensitive but 10% specific. The technique held ground where CT angiography was weak. In 227 patients at Hammersmith Hospital, V/Q scintigraphy found chronic thromboembolic disease with 96% to 97.4% sensitivity against 51% for CTPA, and it remains the recommended screening test for that condition. The same particle became a planning tool for yttrium-90 microsphere therapy.
What the research shows
Accuracy is well documented for planar imaging and for chronic thromboembolic disease; the evidence behind SPECT-based diagnosis, and behind particle-number safety limits in pulmonary vascular disease, is far thinner.
Key findings
- A high-probability planar scan had 88% positive predictive value but only 41% sensitivity for acute pulmonary embolism.
- V/Q scintigraphy detected chronic thromboembolic disease with 96% to 97.4% sensitivity and 90% to 95% specificity, against 51% sensitivity for CTPA.
- Brain uptake of MAA separated hepatopulmonary syndrome from cirrhosis without it: positive in 21 of 25 cases, negative in all 40 controls, with shunt fraction inversely correlated with arterial oxygen (r = -0.726).
- Thirteen accuracy studies of V/Q SPECT were identified, but 11 were at high risk of bias in at least two domains, so pooled accuracy could not be calculated.
- MAA SPECT/CT lung dosimetry was more precise than planar imaging for yttrium-90 planning, with 95% limits of agreement of -1.76 to +2.40 Gy versus -3.48 to +3.31 Gy.
What is still unsettled
No randomised trial has tested whether a management strategy built on V/Q SPECT changes outcomes, and the 2020 review found the accuracy literature too biased to pool, so the most-quoted figures come from older planar cohorts such as PIOPED. The link between particle number and harm in pulmonary hypertension rests on case reports rather than a dose-ranging study, and reaction frequencies cannot be estimated because reporting is voluntary.
Open questions
- What particle number is safe in severe pulmonary hypertension, and can a threshold be tested prospectively rather than inferred from case reports?
- Does a V/Q SPECT-based diagnostic algorithm reduce deaths or unnecessary anticoagulation compared with CT pulmonary angiography?
- Can a synthetic, non-blood-derived particle reproduce MAA's first-pass trapping without new artifacts or supply constraints?
- How should MAA shunt fraction be standardised across cameras and software for hepatopulmonary syndrome and radioembolization planning?
More in this index
- Technetium (99mTc) arcitumomab
- Technetium (99mTc) fanolesomab
- Technetium (99mTc) nofetumomab merpentan
- Technetium (99mTc) pintumomab
- Technetium (99mTc) sulesomab
- Technetium (99mTc) tilmanocept
Sources
- PulmoTech MAA (kit for technetium Tc 99m albumin aggregated) prescribing information, Curium US
- DraxImage MAA prescribing information, Jubilant DraxImage
- MedlinePlus: V/Q Scan
- PIOPED Investigators. Value of the ventilation/perfusion scan in acute pulmonary embolism. JAMA 1990
- Tunariu et al. V/Q scintigraphy versus multidetector CTPA in chronic thromboembolic disease. J Nucl Med 2007
- Le Roux et al. Ventilation/perfusion SPECT for the diagnosis of pulmonary embolism: a systematic review. J Thromb Haemost 2020
- Zareian et al. Lung perfusion imaging in nuclear medicine with 99mTc: a comprehensive survey of radiopharmaceuticals. EJNMMI Radiopharm Chem 2026
- Taplin, Johnson, Dore, Kaplan. Suspensions of radioalbumin aggregates for photoscanning the liver, spleen, lung and other organs. J Nucl Med 1964
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.