Medicine

Technetium (99mTc) albumin aggregated

Albumin particles 10–90 µm wide that lodge in lung capillaries to map blood flow

What it is

Technetium (99mTc) albumin aggregated is a radioactive diagnostic agent, not a treatment. A vial holds human albumin that has been heat-denatured into fragile microscopic clumps and sealed with stannous chloride; minutes before use it is mixed with sodium pertechnetate Tc-99m, which binds to the protein. The finished suspension is injected into a vein. Particle size is the design specification: at least 90% measure 10 to 90 micrometers and none exceed 150. Two US kits, PulmoTech MAA and DraxImage MAA, supply it, each with 2 mg to 2.5 mg of aggregated albumin and millions of particles.

What it does

After labeling, the dose is injected slowly into a vein while the patient already lies under a gamma camera, because extraction by the lung is almost immediate. Adults typically receive about 350,000 particles, within a permitted range of 200,000 to 700,000, and those particles distribute in proportion to regional pulmonary blood flow. A lung segment whose artery is blocked — by a clot in acute pulmonary embolism, or by organized fibrous tissue in chronic thromboembolic disease — receives few particles and shows as a defect. Perfusion images are read alongside a ventilation scan: a perfusion defect with preserved ventilation points to vascular obstruction, while matched defects suggest airway or parenchymal disease such as COPD. The same suspension can be instilled into the peritoneal cavity to follow a peritoneovenous shunt.

How it works

This agent has no receptor, enzyme or transporter target; its target is anatomy. Albumin is heat-denatured with stannous chloride into fragile aggregates, and stannous ion reduces pertechnetate so technetium-99m is held on the protein. Size does the work. Pulmonary capillaries average roughly 5.5 micrometers across, aggregates above 10 to 15 micrometers cannot negotiate them, and the specification requires at least 90% of particles between 10 and 90 micrometers with none above 150. Within 1 to 5 minutes of intravenous injection, more than 90% are trapped in pulmonary arterioles and capillaries on first pass, distributed according to regional blood flow. The blockade is temporary: particles erode and fragment, shrink below the capillary threshold, re-enter the circulation and are cleared by the reticuloendothelial system, with a lung biological half-life of 10.8 hours (range 6.9 to 19, n=5). Technetium-99m decays by isomeric transition with a 6.02-hour physical half-life, emitting a 140.5 keV gamma ray. Aggregates under 10 micrometers bypass the lung and are taken up by liver, spleen and marrow, which is why extrapulmonary uptake signals a right-to-left shunt.

Step by step

What it is used for

Dosing as the label states it

The label states that adults having lung perfusion scintigraphy receive 37 MBq to 148 MBq (1 mCi to 4 mCi) with 200,000 to 700,000 particles, typically about 350,000. Children aged 4 weeks and older receive 0.925 to 1.85 MBq/kg, minimum 7.4 MBq; neonates receive 7.4 to 18.5 MBq with 10,000 to 50,000 particles. For peritoneovenous shunt scintigraphy the label states 37 MBq to 111 MBq (1 mCi to 3 mCi) with 200,000 to 700,000 particles, given intraperitoneally.

What to watch for

Interactions

Avoid if

How it was discovered

Lung perfusion imaging with particles began with George Taplin and colleagues at UCLA. A 1963 laboratory report and a 1964 Journal of Nuclear Medicine paper described suspensions of radioalbumin aggregates that could photoscan the liver, spleen, lung and other organs; lung uptake, a problem for liver imaging, turned out to map pulmonary blood flow. Albumin was already a well-understood plasma protein, and heat denaturation in the presence of stannous chloride produced aggregates that could later be labeled with technetium-99m eluted from a generator.

Approval history

Technetium Tc 99m albumin aggregated has been in routine lung perfusion scintigraphy since the early 1970s and remains the standard agent for it. The DraxImage kit label gives an initial US approval date of 1987; PulmoTech MAA, manufactured by CIS bio International and distributed by Curium, carries a 2020 approval with a modern label specifying pediatric particle tables, age-specific dosimetry and an 18-hour shelf life after labeling. Both products are kits rather than finished drugs: the nuclear pharmacy adds sodium pertechnetate Tc-99m, then assays activity, volume and particle count in a dose calibrator.

Impact

PIOPED fixed the scan's reputation and its limits: among 933 of 1493 patients studied prospectively, a high-probability scan was right 88% of the time, yet only 41% of patients with embolism had one, and any abnormality was 98% sensitive but 10% specific. The technique held ground where CT angiography was weak. In 227 patients at Hammersmith Hospital, V/Q scintigraphy found chronic thromboembolic disease with 96% to 97.4% sensitivity against 51% for CTPA, and it remains the recommended screening test for that condition. The same particle became a planning tool for yttrium-90 microsphere therapy.

What the research shows

Accuracy is well documented for planar imaging and for chronic thromboembolic disease; the evidence behind SPECT-based diagnosis, and behind particle-number safety limits in pulmonary vascular disease, is far thinner.

Key findings

What is still unsettled

No randomised trial has tested whether a management strategy built on V/Q SPECT changes outcomes, and the 2020 review found the accuracy literature too biased to pool, so the most-quoted figures come from older planar cohorts such as PIOPED. The link between particle number and harm in pulmonary hypertension rests on case reports rather than a dose-ranging study, and reaction frequencies cannot be estimated because reporting is voluntary.

Open questions

More in this index

Sources

RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.