Medicine · Radioactive Diagnostic Agent · Radiopharmaceutical Activity [MoA]
Iothalamate Sodium I-125
A trace of radioactive iothalamate measures kidney filtration the way inulin does
What it is
Glofil-125 is sodium iothalamate labelled with iodine-125: a sterile, non-pyrogenic solution injected into a vein so a laboratory can measure how fast the kidneys filter blood. Iothalamate is an old tri-iodinated benzoate — three iodine atoms on one small ring, 635.89 daltons as the sodium salt — that the body neither metabolises nor reabsorbs. The radioactive label is only a tracer, letting a gamma counter follow the molecule into plasma and urine. It treats nothing. The product is a number: the glomerular filtration rate, in millilitres per minute.
What it does
Filtered freely at the glomerulus and then left alone by the tubules, iothalamate is a near-perfect stand-in for inulin, the plant polysaccharide that defined how GFR is measured. A known amount goes in; timed blood and urine samples show how much comes out. Two protocols dominate. In the continuous-infusion (Sigman) method a priming dose is followed by a sustaining infusion at about 0.5 mL/min, 40 to 45 minutes are allowed for equilibration, and three consecutive 15-minute urine collections are made with blood drawn six minutes before each midpoint; GFR is then calculated as UV/P. In the single-injection (Cohen) method 10 to 30 microcuries is injected and three timed urine and plasma pairs over roughly 1.5 to 3 hours are used, with no bladder catheter and no infusion. The label notes that clearance closely approximates inulin's and that effective half-life after infusion is about 0.07 days.
How it works
Strictly speaking, iothalamate has no molecular target. ChEMBL files its mechanism only as "diagnostic agent", with no receptor, enzyme or transporter assigned, and the label describes no pharmacodynamic action at all. Its target is a physical structure: the glomerular filtration barrier, which passes small hydrophilic solutes while holding back cells and large proteins. Three properties decide its behaviour. It is small and compact, 635.89 daltons as the sodium salt, with three iodine atoms on a benzoate ring. It carries a carboxylate and is handled as an inert anion. And, in the label's words, it is "cleared by glomerular filtration without tubular secretion or reabsorption". That last point is the causal hinge: because the tubules neither add nor subtract iothalamate, the amount reaching urine each minute equals the amount filtered, which equals GFR multiplied by plasma concentration. Rearranged, GFR = UV/P. Iodine-125 supplies the readout, decaying by electron capture with a 60.14-day physical half-life and emitting photons a gamma counter can quantify, so activities in plasma and urine become concentrations. The label states that renal clearance of sodium iothalamate "closely approximates that of inulin" and that effective half-life after infusion is about 0.07 days — the tracer leaves the body in hours even though the isotope stays detectable for months.
Step by step
- Injected as a tracer dose — About 1 mg/mL sodium iothalamate carrying 10 to 100 microcuries of iodine-125 enters the circulation; the molecule, not the isotope, governs where it goes.
- Freely filtered — The small hydrophilic benzoate crosses the glomerular barrier into Bowman's space in proportion to the filtration rate.
- No tubular handling — The label states there is no tubular secretion or reabsorption, so urine content per minute equals the filtered load and clearance equals GFR.
- Counted, not chemically assayed — Iodine-125 decays by electron capture with a 60.14-day half-life; gamma counting converts plasma and urine activity into concentrations for UV/P.
- Result — A GFR in mL/min or mL/min/1.73 m2, with an effective half-life of about 0.07 days, so tracer clears within hours.
What it is used for
- Evaluation of glomerular filtration in the diagnosis or monitoring of renal disease
- Confirming kidney function when an estimated GFR is thought unreliable
- Assessing living kidney donors before nephrectomy
- Reference standard for validating creatinine- and cystatin-based eGFR equations
- Measuring renal functional reserve after an oral protein load
Dosing as the label states it
The label states that for an average 70 kg patient the suggested range is 20 to 100 microcuries (0.74 to 3.7 megabecquerels) by continuous intravenous infusion, or 10 to 30 microcuries (0.37 to 1.11 megabecquerels) as a single intravenous injection. It adds that the patient dose should be measured with a suitable radioactivity calibration system immediately before administration, and that rapid or bolus-like injections should be avoided.
What to watch for
- Systemic adverse reactions
- Radiation exposure to the patient and to staff handling the dose
- Thyroid uptake of free iodide in the preparation
- Falsely low GFR from incomplete bladder emptying during timed collections
- Allergic reaction to the injected filtration marker
Interactions
- Lugol's solution or potassium iodide — Given on purpose in the label's single-injection protocol, 3 drops by mouth three times daily for one or two days beforehand, to saturate the thyroid iodine trap and block uptake of free iodide — an additive effect at the same transporter, not an enzyme interaction.
- Other iodinated contrast media given in the same period — Additive iodine load; the label's dosimetry already assumes 1% free iodide and 25% thyroid uptake, so a second iodine source adds to that burden. No shared metabolic pathway exists.
- Diuretics, or dehydration, that change urine flow — This is a timed urine clearance: the label requires urine flow above 3 mL/min, reached with a 1,500 mL oral water load. Changing V in UV/P changes the calculated GFR without changing true filtration.
- Nephrotoxic drugs such as aminoglycosides, amphotericin B or cisplatin — No shared enzyme or transporter is described; these agents lower the filtration rate itself, so the measured value falls. The label contains no drug-interaction section and no formal interaction studies.
- Other radiopharmaceuticals or a repeat iodine-125 measurement — Purely a counting problem: overlapping gamma emissions in the same energy window inflate activity readings, which then distort both U and P.
Avoid if
- You would receive it through a central venous line — this is the label's only stated contraindication.
- You are pregnant — animal reproduction studies were never conducted, fetal harm is unknown, and the label says give only if clearly needed.
- You are breastfeeding — radioiodine is excreted in human milk and the label directs that formula feeding be substituted.
- The patient is a child — safety and effectiveness have not been established.
- Timed urine cannot be collected completely, for example without a catheter or with poor bladder emptying — the clearance calculation depends on complete collections.
How it was discovered
Iothalamate is one of the tri-iodinated benzoates, a family of contrast molecules built around a benzene ring carrying three iodine atoms; PubChem gives the sodium salt as C11H8I3N2NaO4, 635.89 daltons. Its life as a filtration marker began with Sigman and colleagues, whose 1965 paper in Investigative Urology described the renal clearance of 131-I labelled sodium iothalamate in man — the label still calls its infusion protocol the Sigman method. In 1971 Maher, Nolan and Elveback at the Mayo Clinic compared simultaneous clearances of 125-I iothalamate and inulin, the reference standard, and reported them in Mayo Clinic Proceedings.
Approval history
Drugs@FDA records original approval of application NDA017279 on 12 February 1974, with Iso-Tex as sponsor and Glofil-125 as the only listed product, a 250 to 300 microcurie/mL injectable. ChEMBL's record for iothalamate sodium I-125 gives 1982 as a first-approval year and assigns ATC code V09CX03, in the renal-system diagnostic group; the two sources disagree and neither explains why. Whatever the exact date, the product has been on the US market for five decades with a label that still reports no warnings and no adverse reactions.
Impact
Iothalamate clearance became the yardstick against which kidney-function estimates are judged. The CKD-EPI 2009 creatinine equation, which laboratories worldwide adopted, was developed on measured GFR from 8254 participants in 10 studies, with iothalamate as the marker in the development set. A 2014 Swedish systematic review for the SBU group found that renal clearance of iothalamate was the only method meeting its accuracy thresholds with strong evidence. It remains a niche test, used where an estimate could mislead: donor workup, extreme body composition, and trial end points.
What the research shows
Mature and largely settled as a measurement method, with active use as a reference standard rather than as a subject of new drug trials. The open questions are methodological — whether plasma-only clearance can replace urine collections, and how much the test improves outcomes rather than numbers.
Key findings
- Renal clearance of iothalamate was the only GFR method graded as having strong evidence of sufficient accuracy against inulin clearance; plasma iothalamate clearance had insufficient evidence.
- Iothalamate clearance provided the measured GFR for the development dataset of 8254 participants across 10 studies that produced the CKD-EPI creatinine equation, validated in 3896 participants across 16 studies.
- In 260 patients with ADPKD, a combined creatinine-cystatin C slope tracked iothalamate-measured GFR decline more closely than creatinine alone (concordance 0.68 versus 0.58), which translated into 37% to 38% smaller hypothetical trial samples.
- Among 2512 living kidney donors evaluated from 2011 to 2023, about 90% of candidates ruled ineligible by an eGFR equation were reclassified as eligible when measured GFR was used.
What is still unsettled
The evidence base for the test itself is old and small: the 2014 review noted that included studies were few, mostly decades old, and often under 50 participants. Accuracy depends on complete urine collection, which no protocol can verify, and the label's radiation dosimetry table is published as an image, so organ doses could not be checked here. Plasma-only iothalamate clearance — attractive because it avoids urine collection — is explicitly rated as having insufficient evidence.
Open questions
- Can plasma clearance of iothalamate, without any urine collection, be validated well enough to replace the urinary method that currently carries strong evidence?
- Does measuring GFR rather than estimating it actually change clinical outcomes — graft survival, donor safety, drug dosing — or only reclassify patients?
- Is non-radioactive ("cold") iothalamate urinary clearance interchangeable with the iodine-125 version? Both are in use, but no head-to-head comparison appeared in the sources retrieved.
- What is the radiation dose to a child, given that paediatric safety and effectiveness are listed as not established and no paediatric dosimetry is published?
Drug class
Related
- Ammonia N-13
- Choline C-11
- Fludeoxyglucose F-18
- Flutemetamol F-18
- Human Serum Albumin I-131
- Ioflupane I-123
Sources
- GLOFIL-125 (Sodium Iothalamate I-125 Injection) prescribing information, Iso-Tex Diagnostics
- Drugs@FDA application NDA017279 approval record
- MedlinePlus: Estimated Glomerular Filtration Rate (eGFR) and GFR Tests
- Soveri et al., Measuring GFR: a systematic review, Am J Kidney Dis 2014
- Gaspari, Perico & Remuzzi, Measurement of glomerular filtration rate, Kidney Int Suppl 1997
- Levey et al., A new equation to estimate glomerular filtration rate, Ann Intern Med 2009
- PubChem CID 23667529, sodium iothalamate
- ClinicalTrials.gov NCT03190070, renal functional reserve measured with cold iothalamate
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.