Medicine · Radioactive Diagnostic Agent · Radiopharmaceutical Activity [MoA]

Ioflupane I-123

A cocaine-derived tracer that maps dopamine nerve endings and was Schedule II until 2015

What it is

Ioflupane I-123 is a radioactive injection given before a SPECT scan of the brain. Its molecule is a phenyltropane built on the cocaine skeleton and labelled with iodine-123, a gamma emitter with a 13.2-hour half-life. The active mass is microscopic: the US product contains 0.07 to 0.13 micrograms of ioflupane per millilitre, so it traces rather than treats. Marketed as DaTscan, it was approved in Europe in 2000 and the United States in 2011. GE HealthCare manufactures it, and Curium sells a US generic under the same name.

What it does

An injection of ioflupane I-123 is followed, three to six hours later, by a SPECT scan. The tracer crosses the blood-brain barrier and settles on presynaptic dopamine transporters in the striatum, the caudate nucleus and putamen. A normal scan shows two bright comma shapes. When nigrostriatal neurons die, the putamen loses its signal first, so the comma shrinks to a period; the caudate may follow. Radiologists read the result as normal or abnormal, not as a named disease. The label positions it as an adjunct to other evaluations in adults with suspected Parkinsonian syndromes or suspected dementia with Lewy bodies, and it deliberately does not separate Parkinson's disease from multiple system atrophy or progressive supranuclear palsy, nor DLB from other dementias. A normal scan is used to argue against a degenerative Parkinsonian syndrome; an abnormal one supports the diagnosis without naming it.

How it works

The target is the presynaptic dopamine transporter, or DAT. Ioflupane binds it reversibly with a Ki of 0.62 nM and an IC50 of 0.71 nM, and autoradiography of post-mortem human brain shows the label concentrating in the caudate and putamen. The binding is specific: the DAT inhibitor GBR 12909 abolished striatal uptake, while citalopram reduced neocortical and thalamic signal with little striatal effect, and desipramine cut extrastriatal binding by 60 to 85% without touching the striatum, evidence that cortical and thalamic signal comes from serotonin and norepinephrine transporters rather than DAT. Iodine-123 then does the reporting: it decays by electron capture to tellurium-123, emitting a 159 keV gamma photon in 83% of decays, which a gamma camera images. Because DAT sits on the presynaptic membrane of dopaminergic neurons, striatal counts track how many nigrostriatal terminals survive. In Parkinson's disease those neurons die in the substantia nigra, DAT density falls, and the putamen, fed by the most vulnerable projections, dims before the caudate. At tracer mass there is no dopamine effect to feel: no euphoria, no motor change, no high.

Step by step

What it is used for

Dosing as the label states it

The label states 111 MBq to 185 MBq (3 mCi to 5 mCi) intravenously over at least 20 seconds, with a thyroid-blocking agent equivalent to 100 mg iodide at least one hour before, and SPECT imaging 3 to 6 hours after injection.

What to watch for

Interactions

Avoid if

How it was discovered

The tracer came out of cocaine chemistry. In 1994 John Neumeyer and colleagues at Research Biochemicals International in Natick, Massachusetts, published N-omega-fluoroalkyl analogues of beta-CIT, the iodophenyl tropane that imaged dopamine transporters but forced scanning the next day. The fluoropropyl version had faster kinetics. First human SPECT followed at Yale in 1996, when Abi-Dargham's team injected eight volunteers with the fluoropropyl and fluoroethyl compounds and saw striatal uptake peak within half an hour. In Amsterdam, Booij's group had been testing piperazine tracers such as GBR 12909; the cocaine-derived molecules proved better at imaging the living brain.

Approval history

Cygne B.V., an Eindhoven company that became part of Amersham in 1996, began the European marketing application that year with the Amsterdam investigators. Phase I and II studies set safety, biodistribution and imaging time; a multicentre European trial compared parkinsonism with essential tremor. The European Agency for the Evaluation of Medicinal Products approved it in July 2000 as DaTSCAN, launched at the EANM congress in Paris. A GE HealthCare phase III trial supported adding dementia with Lewy bodies in 2007. The FDA approved it in January 2011 for suspected Parkinsonian syndromes and extended it to DLB in November 2022.

Impact

More than 2.5 million patients have been scanned, across 40 countries and over 1,000 destinations, with production in Eindhoven, Arlington Heights, Illinois, and a Japanese plant acquired by GE HealthCare. It became a reference standard: the Movement Disorder Society's 2015 criteria state that a normal DAT scan excludes Parkinson's disease, and the McKeith criteria have listed it as an indicative DLB biomarker since 2005. It anchors the Parkinson's Progression Markers Initiative, launched by the Michael J. Fox Foundation in 2010. PET tracers now compete, but ioflupane remains the only approved dopamine transporter radiopharmaceutical in the US, Japan and Europe.

What the research shows

Approved and widely used, with 37 studies registered on ClinicalTrials.gov. Current work is less about whether the scan works and more about where else it helps: prodromal and at-risk populations, REM sleep behaviour disorder, monogenic Parkinson's, DLB against Alzheimer's disease, and head-to-head comparison with newer PET tracers. The label's own evidence base remains two open-label studies for Parkinsonian syndromes and an autopsy series for DLB.

Key findings

What is still unsettled

The scan shows loss of dopamine terminals, not its cause: it cannot separate Parkinson's disease from multiple system atrophy or progressive supranuclear palsy, and the label says it was not designed to. Whether it can track progression or treatment response is unresolved, and the label states that this use has not been established. Its place against newer PET tracers such as [18F]fluorodopa, [18F]FE-PE2I and [11C]PE2I is still being worked out; head-to-head studies find similar sensitivity in early motor Parkinson's, while PET offers better resolution and shorter scans.

Open questions

Drug class

Related

Sources

RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.