Medicine · Radioactive Diagnostic Agent · Radiopharmaceutical Activity [MoA]
Ioflupane I-123
A cocaine-derived tracer that maps dopamine nerve endings and was Schedule II until 2015
What it is
Ioflupane I-123 is a radioactive injection given before a SPECT scan of the brain. Its molecule is a phenyltropane built on the cocaine skeleton and labelled with iodine-123, a gamma emitter with a 13.2-hour half-life. The active mass is microscopic: the US product contains 0.07 to 0.13 micrograms of ioflupane per millilitre, so it traces rather than treats. Marketed as DaTscan, it was approved in Europe in 2000 and the United States in 2011. GE HealthCare manufactures it, and Curium sells a US generic under the same name.
What it does
An injection of ioflupane I-123 is followed, three to six hours later, by a SPECT scan. The tracer crosses the blood-brain barrier and settles on presynaptic dopamine transporters in the striatum, the caudate nucleus and putamen. A normal scan shows two bright comma shapes. When nigrostriatal neurons die, the putamen loses its signal first, so the comma shrinks to a period; the caudate may follow. Radiologists read the result as normal or abnormal, not as a named disease. The label positions it as an adjunct to other evaluations in adults with suspected Parkinsonian syndromes or suspected dementia with Lewy bodies, and it deliberately does not separate Parkinson's disease from multiple system atrophy or progressive supranuclear palsy, nor DLB from other dementias. A normal scan is used to argue against a degenerative Parkinsonian syndrome; an abnormal one supports the diagnosis without naming it.
How it works
The target is the presynaptic dopamine transporter, or DAT. Ioflupane binds it reversibly with a Ki of 0.62 nM and an IC50 of 0.71 nM, and autoradiography of post-mortem human brain shows the label concentrating in the caudate and putamen. The binding is specific: the DAT inhibitor GBR 12909 abolished striatal uptake, while citalopram reduced neocortical and thalamic signal with little striatal effect, and desipramine cut extrastriatal binding by 60 to 85% without touching the striatum, evidence that cortical and thalamic signal comes from serotonin and norepinephrine transporters rather than DAT. Iodine-123 then does the reporting: it decays by electron capture to tellurium-123, emitting a 159 keV gamma photon in 83% of decays, which a gamma camera images. Because DAT sits on the presynaptic membrane of dopaminergic neurons, striatal counts track how many nigrostriatal terminals survive. In Parkinson's disease those neurons die in the substantia nigra, DAT density falls, and the putamen, fed by the most vulnerable projections, dims before the caudate. At tracer mass there is no dopamine effect to feel: no euphoria, no motor change, no high.
Step by step
- A cocaine-derived tracer is injected — Ioflupane I-123 is N-omega-fluoropropyl-2beta-carbomethoxy-3beta-(4-[123I]iodophenyl)nortropane, given intravenously in microgram mass, so it does not behave like a stimulant drug.
- It binds the presynaptic dopamine transporter — Binding is reversible at the DAT with a Ki of 0.62 nM, and a DAT inhibitor abolishes striatal uptake, confirming the target.
- Iodine-123 emits a gamma photon — The isotope decays by electron capture to tellurium-123 with a 13.2-hour half-life, emitting a 159 keV gamma ray in 83% of decays.
- The camera maps surviving terminals — SPECT acquired 3 to 6 hours after injection records striatal radioactivity in proportion to the density of DAT-bearing nigrostriatal endings.
- Putamen signal loss marks degeneration — In Parkinsonian syndromes the putamen dims before the caudate, turning the normal comma shape into a period, and the scan is read as abnormal.
What it is used for
- Suspected Parkinsonian syndromes
- Suspected dementia with Lewy bodies
- Separating degenerative parkinsonism from essential tremor
- Prodromal and at-risk Parkinson's research
- Monitoring progression or treatment response
Dosing as the label states it
The label states 111 MBq to 185 MBq (3 mCi to 5 mCi) intravenously over at least 20 seconds, with a thyroid-blocking agent equivalent to 100 mg iodide at least one hour before, and SPECT imaging 3 to 6 hours after injection.
What to watch for
- Headache
- Nausea
- Vertigo
- Dry mouth
- Dizziness
- Hypersensitivity reactions including dyspnea, edema, rash, erythema and pruritus
- Thyroid accumulation of iodine-123, with a long-term risk of thyroid neoplasia
- Radiation exposure, an effective dose of 3.94 mSv at 185 MBq in an adult
Interactions
- Amphetamine, methamphetamine, methylphenidate, phentermine, norephedrine and phenylpropanolamine — These bind the dopamine transporter with high affinity and can occupy it, altering the striatal image.
- Cocaine and mazindol — Both are high-affinity dopamine transporter ligands and may interfere with tracer binding.
- Bupropion — It blocks the dopamine and norepinephrine transporters, so it can change the distribution of the tracer.
- Sertraline, paroxetine and citalopram — The label states these selective serotonin reuptake inhibitors may increase or decrease ioflupane binding to the dopamine transporter.
- Selegiline — It binds the dopamine transporter with high affinity and is listed as a potential interferer.
- Amoxapine, benztropine, buspirone, modafinil and armodafinil — Each is a high-affinity dopamine transporter binder named in the label as a possible source of image interference.
- Dopamine agonists and antagonists — The label states that their effects on ioflupane imaging have not been established.
Avoid if
- You have had a serious allergic reaction to ioflupane I-123; known serious hypersensitivity is the labelled contraindication.
- You are pregnant, because the label says the injection may cause fetal harm and at 185 MBq the uterus receives about 3.0 mGy.
- You are breastfeeding and cannot pause, because the label advises interrupting breastfeeding and pumping and discarding milk for at least six days.
- You cannot receive a thyroid-blocking agent, because iodide is given at least an hour beforehand to limit iodine-123 uptake by the thyroid.
How it was discovered
The tracer came out of cocaine chemistry. In 1994 John Neumeyer and colleagues at Research Biochemicals International in Natick, Massachusetts, published N-omega-fluoroalkyl analogues of beta-CIT, the iodophenyl tropane that imaged dopamine transporters but forced scanning the next day. The fluoropropyl version had faster kinetics. First human SPECT followed at Yale in 1996, when Abi-Dargham's team injected eight volunteers with the fluoropropyl and fluoroethyl compounds and saw striatal uptake peak within half an hour. In Amsterdam, Booij's group had been testing piperazine tracers such as GBR 12909; the cocaine-derived molecules proved better at imaging the living brain.
Approval history
Cygne B.V., an Eindhoven company that became part of Amersham in 1996, began the European marketing application that year with the Amsterdam investigators. Phase I and II studies set safety, biodistribution and imaging time; a multicentre European trial compared parkinsonism with essential tremor. The European Agency for the Evaluation of Medicinal Products approved it in July 2000 as DaTSCAN, launched at the EANM congress in Paris. A GE HealthCare phase III trial supported adding dementia with Lewy bodies in 2007. The FDA approved it in January 2011 for suspected Parkinsonian syndromes and extended it to DLB in November 2022.
Impact
More than 2.5 million patients have been scanned, across 40 countries and over 1,000 destinations, with production in Eindhoven, Arlington Heights, Illinois, and a Japanese plant acquired by GE HealthCare. It became a reference standard: the Movement Disorder Society's 2015 criteria state that a normal DAT scan excludes Parkinson's disease, and the McKeith criteria have listed it as an indicative DLB biomarker since 2005. It anchors the Parkinson's Progression Markers Initiative, launched by the Michael J. Fox Foundation in 2010. PET tracers now compete, but ioflupane remains the only approved dopamine transporter radiopharmaceutical in the US, Japan and Europe.
What the research shows
Approved and widely used, with 37 studies registered on ClinicalTrials.gov. Current work is less about whether the scan works and more about where else it helps: prodromal and at-risk populations, REM sleep behaviour disorder, monogenic Parkinson's, DLB against Alzheimer's disease, and head-to-head comparison with newer PET tracers. The label's own evidence base remains two open-label studies for Parkinsonian syndromes and an autopsy series for DLB.
Key findings
- The first human SPECT study injected eight healthy volunteers with the fluoropropyl and fluoroethyl analogues; brain uptake reached 6.37% of the injected dose, and striatal activity peaked within 30 minutes.
- Visual assessment of [123I]FP-CIT SPECT separated parkinsonism from essential tremor in a multicentre European study, the registration evidence for the European application.
- In 55 patients with autopsy-confirmed diagnoses, ioflupane SPECT distinguished dementia with Lewy bodies from Alzheimer's disease with 80% sensitivity and 92% specificity.
- More than 2.5 million patients have been scanned worldwide, and the tracer remains the only approved dopamine transporter radiopharmaceutical in the US, Japan and Europe.
What is still unsettled
The scan shows loss of dopamine terminals, not its cause: it cannot separate Parkinson's disease from multiple system atrophy or progressive supranuclear palsy, and the label says it was not designed to. Whether it can track progression or treatment response is unresolved, and the label states that this use has not been established. Its place against newer PET tracers such as [18F]fluorodopa, [18F]FE-PE2I and [11C]PE2I is still being worked out; head-to-head studies find similar sensitivity in early motor Parkinson's, while PET offers better resolution and shorter scans.
Open questions
- Can an abnormal scan in REM sleep behaviour disorder predict conversion to Parkinson's disease reliably enough to enrol people in prevention trials?
- Why does the putamen lose signal before the caudate, and can that gradient be used to stage disease rather than simply detect it?
- Will newer PET tracers displace ioflupane, given that it remains the only approved dopamine transporter agent in the US, Japan and Europe?
- Does dopamine transporter loss on imaging track clinical progression closely enough to serve as an endpoint in disease-modifying trials?
Drug class
Related
- Ammonia N-13
- Choline C-11
- Fludeoxyglucose F-18
- Flutemetamol F-18
- Human Serum Albumin I-131
- Iothalamate Sodium I-125
Sources
- DailyMed: Ioflupane I 123 Injection prescribing information
- ChEMBL compound record CHEMBL3989517
- Booij et al., Let's celebrate 25 years of [123I]I-FP-CIT SPECT (2026)
- Neumeyer et al., N-omega-fluoroalkyl analogues of beta-CIT (1994)
- Abi-Dargham et al., SPECT imaging of dopamine transporters in human brain (1996)
- DEA final rule removing [123I]ioflupane from Schedule II (2015)
- ClinicalTrials.gov: registered studies of ioflupane I-123
- Wikipedia: Ioflupane (123I)
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.