Umirolimus
A rapamycin derivative with no pill form, coated onto stents to stop vessel-wall regrowth
What it is
Umirolimus, also called biolimus A9 and listed as 40-O-(2-ethoxyethyl)rapamycin, is a macrocyclic lactone built from sirolimus. Its formula is C55H87NO14 and its molecular weight 986.3; ChEMBL gives an alogP of 7.24, the lipophilicity that lets it load into an artery wall. Biosensors International owns the compound and licenses it to partners including Terumo. It has no tablet, capsule or injection: every clinical use is as the active coating of a coronary stent. ChEMBL records a maximum clinical phase of 2 and no first-approval date for the molecule.
What it does
Once a stent is pressed against the artery wall, umirolimus leaves the coating and partitions into the tissue it touches. On the polymer-free BioFreedom stent the drug moves into the vessel wall over about one month, the interval that matched the one-month dual antiplatelet course used in the LEADERS FREE trial. Because the molecule is highly lipophilic it is taken up quickly by smooth muscle cells, which is why stent doses are lower than the systemic doses used for oral rapamycin analogues. Inside those cells it halts the division that would otherwise narrow the artery again, the neointimal hyperplasia behind in-stent restenosis. It also suppresses T-cell proliferation, a property shared with sirolimus, although a stent-bound dose is meant to act locally rather than throughout the body. Two carrier designs exist: a biodegradable polylactic-acid coating and a polymer-free, carrier-free surface.
How it works
Umirolimus binds FKBP12, the cytosolic immunophilin named for its affinity for tacrolimus, formerly FK-506. The umirolimus-FKBP12 complex then engages mTOR, the kinase that governs cell growth, and blocks the signals that would otherwise move a smooth muscle cell out of G1 and into DNA synthesis. The cell arrests in G0/G1. The sequence begins further upstream, when growth factors such as PDGF, bFGF and thrombin bind receptors on the smooth muscle cell; umirolimus interrupts the signalling that follows, not the binding itself. With division blocked, the arterial wall cannot build the new tissue layer that narrows a stented segment, so the lumen stays wider. The same FKBP12-mTOR step operates in T cells, which explains the immunosuppression produced by systemic sirolimus analogues; with stent delivery the exposure is local and short-lived. Two consequences follow from the chemistry. First, the 2-ethoxyethyl group at position 40 makes umirolimus far more lipophilic than sirolimus, so it enters the vessel wall rapidly and is retained there. Second, the class effect on endothelium is less helpful: limus drugs impair the endothelial barrier and slow coverage of stent struts, the mechanistic reason late stent thrombosis remains a concern even when restenosis falls.
Step by step
- Sit in the coating — Umirolimus is bound in a biodegradable polymer or held on a polymer-free, carrier-free stent surface.
- Cross into the wall — The highly lipophilic drug leaves the strut and partitions into adjacent smooth muscle cells over roughly a month.
- Bind FKBP12 — Inside the cytosol it forms a complex with the immunophilin FKBP12.
- Block mTOR — That complex inhibits mTOR signalling, so cells arrest in G0/G1 instead of entering S phase.
- Limit neointima — Fewer dividing smooth muscle cells means less tissue growth inside the stent and a wider lumen.
What it is used for
- Coronary revascularisation with a drug-eluting stent
- Primary PCI for ST-elevation myocardial infarction
- PCI in people at high bleeding risk, with one month of dual antiplatelet therapy
- Chronic total occlusion PCI
What to watch for
- Target-lesion revascularisation, a repeat procedure for restenosis
- Composite of cardiac death, myocardial infarction or stent thrombosis
- Stent thrombosis
- Myocardial infarction
- Bleeding while on dual antiplatelet therapy
- Delayed or incomplete endothelial coverage of stent struts
Interactions
- Aspirin — Additive platelet inhibition on top of the stent's local drug effect; the combination drives gastrointestinal and access-site bleeding.
- Clopidogrel — Second antiplatelet in the dual regimen; additive P2Y12 blockade raises bleeding risk, with no documented metabolic interaction with umirolimus.
- Ticagrelor — Potent P2Y12 blockade added to aspirin; the interaction is additive bleeding rather than a shared enzyme pathway.
- Prasugrel — Same additive antiplatelet effect; stronger platelet inhibition means more bleeding across the one-month or longer stent course.
Avoid if
- Active bleeding or a recent major haemorrhage, because the stent requires dual antiplatelet therapy that would add to that risk.
- Known hypersensitivity to rapamycin analogues or to the stent's polymer or metal components, because umirolimus is a sirolimus derivative carried on a device.
- A planned procedure or condition that prevents completing the prescribed antiplatelet course, because interrupting it leaves the struts exposed to thrombosis.
How it was discovered
Rapamycin, the parent molecule, comes from the soil bacterium Streptomyces hygroscopicus. Chemists produced umirolimus by adding a 2-ethoxyethyl group at position 40 of the rapamycin ring, yielding a macrocyclic lactone of molecular weight 986.3. Biosensors International held the compound, named it biolimus A9, and licensed it to partners including Terumo. Unlike sirolimus, everolimus and zotarolimus, it was developed from the outset for coronary stent use rather than repurposed from transplant medicine, which is why its whole clinical record sits in interventional cardiology.
Approval history
There is no licensed umirolimus medicine. ChEMBL lists a maximum clinical phase of 2 and no first-approval date, and FDA drug records return no umirolimus product. Its regulatory life has run through devices: biodegradable-polymer BioMatrix and Nobori stents and the polymer-free BioFreedom stent carry CE marks in Europe. The cobalt-chromium BioMatrix Alpha received CE-mark approval in 2015 through a pathway that did not require a new clinical trial, on the strength of its similarity to the earlier stent.
Impact
Two trials gave the molecule its clinical identity. LEADERS randomised 1707 patients across ten European centres and found a biodegradable-polymer biolimus stent non-inferior to a durable-polymer sirolimus stent at nine months. LEADERS FREE then compared a polymer-free umirolimus-coated stent with a bare-metal stent in 2466 patients at high bleeding risk, all on one month of dual antiplatelet therapy, and reported fewer cardiac deaths, infarctions or stent thromboses. Biolimus became the limus drug most used in biodegradable-polymer and polymer-free stents, a position built on pairing a lipophilic drug with a short antiplatelet requirement.
What the research shows
Device research is extensive; drug research is not. Thirty-six registered studies involve umirolimus, nearly all stent comparisons, and the largest randomised trials date from 2008 to 2015. No trial tests umirolimus as a systemic medicine, matching a ChEMBL record that stops at phase 2.
Key findings
- A biodegradable-polymer biolimus stent was non-inferior to a durable-polymer sirolimus stent: the 9-month composite of cardiac death, myocardial infarction or target-vessel revascularisation occurred in 9% versus 11% of 1707 patients.
- In STEMI, major adverse cardiac events at one year were 4.3% with a biolimus stent versus 8.7% with a bare-metal stent among 1161 patients.
- Against a durable-polymer everolimus stent, the 12-month composite was 5.2% versus 4.8% in 2707 patients, meeting non-inferiority.
- In 2466 patients at high bleeding risk on one month of dual antiplatelet therapy, the safety composite was 9.4% versus 12.9% and target-lesion revascularisation 5.1% versus 9.8%, both favouring the drug-coated stent over a bare-metal stent.
What is still unsettled
The trials compare whole stent systems, not the drug alone, so how much of each result belongs to umirolimus rather than the polymer, strut thickness or coating method cannot be separated. Pivotal follow-up runs from about one to four years, and no randomised comparison against the newest thin-strut platforms reports long-term stent-thrombosis endpoints.
Open questions
- How much of the outcome difference belongs to umirolimus itself, and how much to the polymer or strut design that carries it?
- Does the advantage over bare-metal stents hold beyond four years, particularly for very late stent thrombosis?
- Can one month of dual antiplatelet therapy be shortened further, or replaced by a single antiplatelet drug, without losing the safety advantage?
- What systemic exposure results from multiple overlapping stents, and does it have any immunological consequence?
More in this index
Sources
- ChEMBL compound report card: umirolimus (CHEMBL2107380)
- Wikipedia: Umirolimus
- ClinicalTrials.gov: umirolimus studies
- LEADERS trial, Lancet 2008
- LEADERS FREE trial, New England Journal of Medicine 2015
- COMPARE II trial, Lancet 2013
- COMFORTABLE AMI trial, JAMA 2012
- BioMatrix Alpha post-market registry, 2020
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.