Medicine
LeukoScan
A mouse-antibody tracer that images osteomyelitis across Europe but never won FDA approval
What it is
LeukoScan is a diagnostic radiopharmaceutical rather than a therapy: sulesomab, an anti-human mouse monoclonal antibody, chemically coupled to a technetium-99m radionuclide. The antibody arm binds NCA-90, a granulocyte-associated cell antigen, so the technetium label travels wherever those white cells gather. It is given intravenously and read with a gamma camera, yielding whole-body pictures of granulocyte infiltration and activation rather than anatomical structure. It holds approval in European markets for imaging infection and inflammation in patients with suspected osteomyelitis, and it has not secured FDA approval for use in American markets. Blood sampling shows total clearance reported at 48-hour time points, indicating limited retention in circulation.
What it does
Function here is measurement, not treatment. After intravenous administration the antibody conjugate circulates, encounters NCA-90-bearing granulocytes, and binds them; the technetium-99m atom carried on each antibody emits gamma rays that a gamma camera localises, building a three-dimensional map of where the labelled cells sit. Because the signal follows cells instead of anatomy, a region with granulocyte infiltration and activation reads hot against quiet tissue — the property that makes the agent useful where structural imaging leaves infection and inflammation ambiguous. The approved European use is suspected osteomyelitis, where bone and overlying soft-tissue infection can be hard to separate. Clinicians read the distribution as a whole-body measurement of granulocyte behaviour, not of bone damage or blood flow. The pharmacokinetics support that read: total clearance from blood samples has been reported at 48-hour time points, so the circulating fraction falls away and does not swamp the image with blood-pool activity.
How it works
Target first: NCA-90, a cell-surface antigen associated with granulocytes. Sulesomab is an anti-human mouse monoclonal antibody directed at that antigen, and each antibody molecule carries a conjugated technetium-99m radionuclide. The chain runs from binding to picture. The antibody's antigen-binding arms engage NCA-90 on the granulocyte surface; nothing needs to enter the cell, because the readout is external. Technetium-99m is a gamma-emitting radionuclide, and a gamma camera images the photons it gives off. Because the emitter is tethered to an antibody that is itself tethered to a granulocyte, photon emission concentrates wherever granulocytes concentrate. Granulocytes marginate and accumulate at sites of infection and inflammation, so those sites appear as hot spots against a cooler background. The result is described as sensitive and specific whole-body measurement of granulocyte infiltration and activation — the agent reports cell behaviour, not bone destruction, oedema or perfusion. Clearance closes the chain: reported total clearance from blood at 48-hour time points means the circulating fraction declines, sharpening the target-to-background ratio and limiting how long the agent stays in circulation.
Step by step
- Antibody binds NCA-90 — The anti-human mouse monoclonal antibody sulesomab engages the granulocyte-associated NCA-90 cell antigen on circulating and marginated granulocytes.
- Technetium-99m rides along — A technetium-99m radionuclide is conjugated to the antibody, so the gamma emitter is physically carried to wherever the antibody binds.
- Granulocytes accumulate at the lesion — Granulocyte infiltration and activation at sites of infection and inflammation draw the labelled cells, and the tracer with them, into the lesion.
- Gamma camera localises the emission — Photons from the bound technetium-99m are imaged externally, converting cell distribution into a whole-body hot-spot map.
- Blood clearance improves contrast — Total clearance reported at 48-hour time points removes circulating tracer, so lesion signal stands out against background.
What it is used for
- Suspected osteomyelitis
- Combat-related musculoskeletal infection
- Diabetic foot infection
- Cardiac and vascular infectious disease
- Neutrophil imaging in cancer
What to watch for
- Anaphylaxis attributed to the murine antibody component; a case was published in 2024 in the Journal of Investigational Allergology and Clinical Immunology.
- Repeat exposure in a patient already sensitised to mouse-derived antibody proteins, where the same reaction pathway would be engaged again.
- Radiation exposure carried by the technetium-99m radionuclide conjugated to the antibody, incurred for a diagnostic rather than therapeutic purpose.
- A lesion read as negative because little granulocyte infiltration was present for the antibody to bind, since the image reports cell accumulation rather than tissue damage.
- Reduced lesion contrast while tracer still circulates, before the clearance reported at 48-hour time points has removed background activity.
Interactions
- Corticosteroids or other drugs that blunt granulocyte traffic to inflamed tissue — The image is a map of granulocyte infiltration and activation, so suppressing that infiltration removes the signal the antibody is designed to carry.
- Antibacterial therapy started before imaging — Treating the infection reduces the granulocyte response being measured, which can flatten a lesion that would otherwise register as a hot spot.
- Other mouse-derived antibodies, whether diagnostic or therapeutic — Prior exposure to murine protein is the sensitisation route behind the reported anaphylaxis to this agent's mouse antibody.
- Other technetium-99m radiopharmaceuticals given in the same imaging session — Two agents emitting at the technetium-99m energy would be indistinguishable to the gamma camera, since localisation depends on the antibody and not on the isotope's decay signature.
Avoid if
- A previous severe hypersensitivity reaction to a mouse-derived antibody, the pattern reported as anaphylaxis to murine antibodies in sulesomab.
- Documented sensitisation to murine antibody protein from earlier imaging or antibody therapy, which puts the same antigen-binding protein back into circulation.
- The clinical question can be answered without a granulocyte-targeted scan, since the technetium-99m label delivers radiation dose for a purely diagnostic readout.
How it was discovered
The design problem was how to see inflammation without opening the patient. Labelled autologous white cells answered it but demanded blood handling and ex vivo labelling, so the alternative was an antibody that finds granulocytes in the body. Sulesomab is that antibody: an anti-human mouse monoclonal raised against the granulocyte-associated NCA-90 cell antigen, with a technetium-99m radionuclide conjugated to it. The pairing was deliberate — a murine immunoglobulin for avidity at the cell surface, and a gamma-emitting isotope whose photons escape tissue for external detection. The result reads as a whole-body measurement of granulocyte infiltration and activation by gamma camera imaging of the antibody-bound cells.
Approval history
LeukoScan reached market in European jurisdictions, where it is authorised for imaging infections and inflammations in patients with suspected osteomyelitis. The American pathway did not follow: the product has not secured FDA approval for use in American markets, so the same antibody-isotope pair is a routine diagnostic option in one regulatory region and an unapproved agent in another. For a radiopharmaceutical this split is consequential in a way it would not be for a tablet, because gamma-camera workflows, reimbursement and referral patterns are built around locally licensed tracers. The evidence base reflects that geography — the diagnostic studies and reviews discussing sulesomab sit largely in European and military-medicine journals rather than in FDA-facing labelling.
Impact
Its footprint is narrow but durable. Sulesomab occupies the niche where a functional read of granulocyte behaviour beats structural imaging: suspected bone infection, combat-related musculoskeletal wounds, diabetic foot infection, and cardiac or vascular infection, each of which has attracted reviews and diagnostic studies that name it. The exit profile supports single-session logistics — total clearance from blood has been reported at 48-hour time points, indicating limited retention in circulation. Against that sits a safety signal specific to its mouse origin, with severe anaphylaxis to murine antibodies reported in 2024. Europe PMC returns roughly 125 records for the agent, a literature large enough to sustain reviews and small enough that no systematic review has consolidated it.
What the research shows
Literature-only and thinly synthesised. Europe PMC holds about 125 records mentioning sulesomab, including diagnostic-accuracy studies and narrative reviews, but no systematic review matched a title search, ClinicalTrials.gov returned zero registered studies, and no FDA label exists to anchor the evidence. What exists is a set of indication-specific imaging evaluations rather than a consolidated body of comparative evidence.
Key findings
- Antigranulocyte scintigraphy with Tc-99m-sulesomab was assessed for diagnosing combat-related infections of the musculoskeletal system.
- Sulesomab was included among the functional imaging tracers reviewed for evaluating diabetic foot infection.
- Single photon emission tomography with agents including sulesomab was reviewed for diagnostic assessment of cardiac and vascular infectious diseases.
- Neutrophil imaging, with sulesomab discussed among the tracers, was reviewed for its clinical translation and role in cancer.
- Severe anaphylaxis to murine antibodies in sulesomab was reported as a clinical case.
What is still unsettled
Whether the antibody image outperforms labelled autologous leukocyte scintigraphy, MRI or combined structural-functional reading in suspected osteomyelitis has not been settled by a prospective head-to-head study with culture or histology as the reference standard — and the 2024 anaphylaxis report leaves the frequency of murine-antibody hypersensitivity in this specific product unquantified.
Open questions
- How often does hypersensitivity to the mouse antibody occur across the full treated population, given that the published signal is a single 2024 anaphylaxis case?
- In suspected osteomyelitis, how does sulesomab scintigraphy compare with labelled leukocyte imaging and MRI when both are read against culture or histology?
- Does granulocyte suppression by corticosteroids or by antibacterials started before the scan measurably reduce diagnostic yield, and over what interval?
- Why did a product authorised in Europe for osteomyelitis imaging never obtain FDA approval, and does the European evidence base explain the gap?
More in this index
Sources
- Technetium (99mTc) sulesomab — Wikipedia
- Europe PMC literature search: sulesomab (about 125 records)
- Severe anaphylaxis to murine antibodies in sulesomab (2024)
- Antigranulocyte scintigraphy with Tc-99m-sulesomab in combat-related musculoskeletal infection (2021)
- Update on functional imaging in the evaluation of diabetic foot infection (2021)
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.