Medicine

Jeanatope

Jeanatope: the iodine-125 albumin tracer that measures blood volume by dilution

What it is

Jeanatope is a radiopharmaceutical: human serum albumin carrying iodine-125, supplied as a sterile intravenous injection in multi-dose vials. Each millilitre holds about 10 mg of albumin and either 0.37 or 37 MBq (10 or 1,000 microCi) of activity at calibration, in phosphate-buffered saline with 9 mg benzyl alcohol as preservative. Its one approved use, in adults, is measuring total blood and plasma volume. The protein is the vehicle and the radioiodine is the signal; the albumin dose is milligrams, far below the grams used to expand plasma, so the injection measures the circulation rather than filling it.

What it does

Jeanatope turns an inaccessible number into arithmetic. A small volume of labelled albumin is injected into a large arm vein; because albumin is the dominant plasma protein and crosses capillary walls slowly, it stays almost entirely within the bloodstream while mixing through the intravascular pool in about ten minutes. Blood drawn from the opposite arm at five and fifteen minutes is counted, the two counts are plotted on semilog paper, and the line is extended back to the instant of injection, before labelled protein has had time to escape into lymph and tissue. Reference activity from a 1:4,000 dilution of the same dose, divided by the zero-time concentration, gives the dilution volume: whole blood if whole blood is counted, plasma if the sample is centrifuged first. No height, weight or haematocrit estimate enters the result.

How it works

The target is a dilution volume, not a receptor. Iodine-125 decays by electron capture with a physical half-life of 60.14 days, emitting a 35 keV gamma photon in 6.7% of disintegrations and characteristic X-rays with a weighted mean near 28 keV, often more than one per decay; a gamma counter reads that flux from a 1 mL aliquot. The radionuclide rides on human serum albumin, a soluble plasma protein that leaves the vascular space only slowly, so its concentration after mixing reports the plasma volume in which it is dissolved. Injecting into one arm and sampling the other avoids counting the bolus itself. Within ten minutes the labelled protein has filled the intravascular pool; extravascular distribution then proceeds for two to four days until equilibrium. Sampling at five and fifteen minutes and extrapolating to zero time removes the distortion from that early leakage. Whole-blood counts against the reference dilution give total blood volume, because the tracer occupies only the plasma fraction; centrifuged plasma gives plasma volume directly. The label reports a biological half-life near 14 days, urinary excretion of almost all activity, and about 2% in faeces. For the patient, the whole procedure is one injection and two blood draws from the arm on the other side, ending in a volume reported in millilitres.

Step by step

What it is used for

Dosing as the label states it

The label states: 0.185 to 1.85 MBq (5 to 50 microCi) intravenously for total blood or plasma volume determination in adults; no more than 7.4 MBq (200 microCi) in any one week when a determination is repeated; and 10 drops of Strong Iodine Solution USP three times daily, starting at least 24 hours before the injection and continuing for one to two weeks, to limit thyroid uptake of the radioiodine.

What to watch for

Interactions

Avoid if

How it was discovered

Radioiodinated human serum albumin entered clinical measurement in 1950, when two teams published plasma volumes obtained with the tracer: Storaasli, Krieger, Friedell and Holden in Surgery, Gynecology & Obstetrics, and Crispell, Porter and Nieset in the Journal of Clinical Investigation. Two years later Solomon Berson and Rosalyn Yalow, who went on to invent radioimmunoassay and bring Yalow the 1977 Nobel Prize, injected iodine-131 albumin alongside potassium-42 or phosphorus-32 labelled red cells to measure both volumes in the same person. In 1953 Schultz and colleagues set the new tracer against the Evans blue dye method. Iodine-125, with its 60-day half-life and photons a well counter can read, made the same tracer practical for studies spread over weeks rather than days.

Approval history

Jeanatope was licensed on 23 February 1976 as BLA 017836, one of three blood-volume biologics approved that day: Chromalbin (chromium-51 chromated albumin, BLA 017835) and Megatope (iodine-131 albumin, BLA 017837) are its siblings. The current labeling was revised in 2023 under supplement 009, and the license now sits with Iso-Tex Diagnostics of Alvin, Texas. The 1,000 microCi/mL vial, NDC 50914-7733-5, carries a marketing end date of 28 November 2024 in the DailyMed listing.

Impact

The dilution principle Jeanatope embodies became the yardstick for what followed. Investigators still use iodine-125 plasma volume as the reference when testing replacements: the 2024 cirrhosis study found a weight-and-haematocrit formula underestimated measured plasma volume by about 0.9 litres, and the 2026 CO-rebreathing review proposed validating that device against technetium-99m and iodine-125 albumin. In routine care the technique has largely given way to dual-isotope red-cell methods, carbon-monoxide rebreathing and bedside monitors, leaving the tracer as a specialist and research instrument.

What the research shows

Jeanatope has no trials of its own. ClinicalTrials.gov returns no registered study of the product or of iodinated I-125 albumin, and no systematic review addresses it; the evidence is methodological, built from method-comparison papers running from 1950 to 2024 in which the tracer is the comparator rather than the intervention.

Key findings

What is still unsettled

No prospective study shows that acting on an iodine-125 albumin measurement changes outcomes, so the number's clinical value rests on plausibility rather than trial evidence. Accuracy depends on an assumption that leaks: albumin leaves the vascular space faster in sepsis, burns and after major surgery, precisely the patients whose volume status is most contested. Large-vessel haematocrit differs from whole-body haematocrit, which is why plasma-derived red-cell volumes historically ran high. The result is also only as good as two timed samples and a correctly diluted standard.

Open questions

More in this index

Sources

RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.