Jeanatope: the iodine-125 albumin tracer that measures blood volume by dilution
What it is
Jeanatope is a radiopharmaceutical: human serum albumin carrying iodine-125, supplied as a sterile intravenous injection in multi-dose vials. Each millilitre holds about 10 mg of albumin and either 0.37 or 37 MBq (10 or 1,000 microCi) of activity at calibration, in phosphate-buffered saline with 9 mg benzyl alcohol as preservative. Its one approved use, in adults, is measuring total blood and plasma volume. The protein is the vehicle and the radioiodine is the signal; the albumin dose is milligrams, far below the grams used to expand plasma, so the injection measures the circulation rather than filling it.
What it does
Jeanatope turns an inaccessible number into arithmetic. A small volume of labelled albumin is injected into a large arm vein; because albumin is the dominant plasma protein and crosses capillary walls slowly, it stays almost entirely within the bloodstream while mixing through the intravascular pool in about ten minutes. Blood drawn from the opposite arm at five and fifteen minutes is counted, the two counts are plotted on semilog paper, and the line is extended back to the instant of injection, before labelled protein has had time to escape into lymph and tissue. Reference activity from a 1:4,000 dilution of the same dose, divided by the zero-time concentration, gives the dilution volume: whole blood if whole blood is counted, plasma if the sample is centrifuged first. No height, weight or haematocrit estimate enters the result.
How it works
The target is a dilution volume, not a receptor. Iodine-125 decays by electron capture with a physical half-life of 60.14 days, emitting a 35 keV gamma photon in 6.7% of disintegrations and characteristic X-rays with a weighted mean near 28 keV, often more than one per decay; a gamma counter reads that flux from a 1 mL aliquot. The radionuclide rides on human serum albumin, a soluble plasma protein that leaves the vascular space only slowly, so its concentration after mixing reports the plasma volume in which it is dissolved. Injecting into one arm and sampling the other avoids counting the bolus itself. Within ten minutes the labelled protein has filled the intravascular pool; extravascular distribution then proceeds for two to four days until equilibrium. Sampling at five and fifteen minutes and extrapolating to zero time removes the distortion from that early leakage. Whole-blood counts against the reference dilution give total blood volume, because the tracer occupies only the plasma fraction; centrifuged plasma gives plasma volume directly. The label reports a biological half-life near 14 days, urinary excretion of almost all activity, and about 2% in faeces. For the patient, the whole procedure is one injection and two blood draws from the arm on the other side, ending in a volume reported in millilitres.
Step by step
- Injection and mixing — Between 0.185 and 1.85 MBq (5 to 50 microCi) enters a large arm vein; the labelled albumin distributes through the intravascular pool within about ten minutes.
- Two early samples — Blood is drawn from the opposite arm at five and fifteen minutes, while nearly all of the tracer is still inside the vessels.
- Back-extrapolation — The two counts are plotted on a semilog axis and the line is carried back to zero time, reconstructing the concentration at the moment of injection and cancelling the effect of albumin already leaking into tissue.
- Gamma counting — A counter reads the 27 to 35 keV emissions from 1 mL of blood or plasma and from a 1:4,000 dilution of the injected dose, both in the same geometry.
- Division — Reference activity divided by the zero-time concentration gives blood volume from whole blood, or plasma volume from centrifuged plasma; no anthropometric estimate is used.
What it is used for
- Total blood volume in adults
- Plasma volume in adults
- Repeat measurements during surgery, critical illness or dialysis
- Reference standard for plasma volume in cirrhosis
- Validation comparator for carbon-monoxide rebreathing and other devices
- Cisternography or any intrathecal use
Dosing as the label states it
The label states: 0.185 to 1.85 MBq (5 to 50 microCi) intravenously for total blood or plasma volume determination in adults; no more than 7.4 MBq (200 microCi) in any one week when a determination is repeated; and 10 drops of Strong Iodine Solution USP three times daily, starting at least 24 hours before the injection and continuing for one to two weeks, to limit thyroid uptake of the radioiodine.
What to watch for
- Hypersensitivity reaction, the only reaction listed under Adverse Reactions
- Aseptic meningitis and pyrogenic reaction, reported when the product was given intrathecally for cisternography
- Permanent impairment of fetal thyroid function
- Transient hypothyroidism in a breastfed infant
- Radiation dose: 0.15 rad to blood and 0.025 to 0.035 rad to the whole body after 50 microCi
- Thyroid uptake of iodide liberated from the tracer, the reason for the Lugol's premedication
- Bruising or leakage of tracer at the injection site
Interactions
- An earlier iodine-125 blood-volume determination — Residual activity in the blood adds to the post-injection counts and shrinks the calculated volume; the label requires a pre-injection background sample and a weekly ceiling of 200 microCi.
- Other radiopharmaceuticals, such as iodine-131 albumin, technetium-99m albumin or chromium-51 red cells — Activity from a tracer in the same compartment or the same counting window is read as part of the new dose, which the reference dilution cannot account for.
- Intravenous fluids, albumin solutions, plasma expanders, diuretics and ultrafiltration — They change the plasma volume being measured, so the result describes the moment of sampling rather than the state the clinician meant to assess.
- Iodinated contrast media, amiodarone, potassium iodide and iodine-rich supplements — They load the body with stable or radioactive iodine and compete with iodide released from the tracer for thyroid uptake, changing thyroid dosimetry rather than blood counts.
- Thyroid-blocking drugs: methimazole, propylthiouracil, perchlorate — Blocking organification of iodide keeps the freed iodine-125 out of thyroid hormone and lowers the thyroid radiation dose, the same purpose as the label's Lugol's regimen.
- Sepsis, burns and major surgery — Albumin escapes the vascular space faster in these states, so a two-point extrapolation over ten minutes is fitting a steeper curve than the one the formula assumes.
Avoid if
- Pregnancy: iodine-125 crosses the placenta and can permanently impair fetal thyroid function, and labeling permits use only when clearly needed, with a thyroid-blocking agent given first.
- Breastfeeding: iodine-125 appears in human milk, and labeling advises stopping breastfeeding because of the risk of transient hypothyroidism in the infant.
- A previous allergic reaction to human serum albumin or to benzyl alcohol, the preservative in the vial.
- Blood cannot be sampled at both five and fifteen minutes, which leaves the zero-time extrapolation without its second point.
- Another blood-volume study in the same week would carry cumulative activity past 7.4 MBq (200 microCi).
- The proposed use is cisternography or another intrathecal route, which is not approved and has been followed by aseptic meningitis.
How it was discovered
Radioiodinated human serum albumin entered clinical measurement in 1950, when two teams published plasma volumes obtained with the tracer: Storaasli, Krieger, Friedell and Holden in Surgery, Gynecology & Obstetrics, and Crispell, Porter and Nieset in the Journal of Clinical Investigation. Two years later Solomon Berson and Rosalyn Yalow, who went on to invent radioimmunoassay and bring Yalow the 1977 Nobel Prize, injected iodine-131 albumin alongside potassium-42 or phosphorus-32 labelled red cells to measure both volumes in the same person. In 1953 Schultz and colleagues set the new tracer against the Evans blue dye method. Iodine-125, with its 60-day half-life and photons a well counter can read, made the same tracer practical for studies spread over weeks rather than days.
Approval history
Jeanatope was licensed on 23 February 1976 as BLA 017836, one of three blood-volume biologics approved that day: Chromalbin (chromium-51 chromated albumin, BLA 017835) and Megatope (iodine-131 albumin, BLA 017837) are its siblings. The current labeling was revised in 2023 under supplement 009, and the license now sits with Iso-Tex Diagnostics of Alvin, Texas. The 1,000 microCi/mL vial, NDC 50914-7733-5, carries a marketing end date of 28 November 2024 in the DailyMed listing.
Impact
The dilution principle Jeanatope embodies became the yardstick for what followed. Investigators still use iodine-125 plasma volume as the reference when testing replacements: the 2024 cirrhosis study found a weight-and-haematocrit formula underestimated measured plasma volume by about 0.9 litres, and the 2026 CO-rebreathing review proposed validating that device against technetium-99m and iodine-125 albumin. In routine care the technique has largely given way to dual-isotope red-cell methods, carbon-monoxide rebreathing and bedside monitors, leaving the tracer as a specialist and research instrument.
What the research shows
Jeanatope has no trials of its own. ClinicalTrials.gov returns no registered study of the product or of iodinated I-125 albumin, and no systematic review addresses it; the evidence is methodological, built from method-comparison papers running from 1950 to 2024 in which the tracer is the comparator rather than the intervention.
Key findings
- Two independent groups published plasma volumes measured with radioiodinated human serum albumin in the same year, opening the field.
- Iodine-131 albumin and labelled red cells were measured simultaneously in the same subjects, fixing the distinction between plasma volume and red-cell volume.
- The tracer was compared directly with the Evans blue (T-1824) dye method in the same patients, the standard plasma-volume technique of the period.
- In septic shock, plasma volume is taken as 98% of the 10-minute volume of distribution of iodine-125 albumin, and a 20% albumin bolus estimated it with limits of agreement of -16% to +11%.
- In 328 patients with cirrhosis, iodine-125 plasma volume averaged 3.99 +/- 1.01 L while a weight-and-haematocrit formula averaged 3.09 +/- 0.54 L, a systematic underestimate of about 0.9 L.
What is still unsettled
No prospective study shows that acting on an iodine-125 albumin measurement changes outcomes, so the number's clinical value rests on plausibility rather than trial evidence. Accuracy depends on an assumption that leaks: albumin leaves the vascular space faster in sepsis, burns and after major surgery, precisely the patients whose volume status is most contested. Large-vessel haematocrit differs from whole-body haematocrit, which is why plasma-derived red-cell volumes historically ran high. The result is also only as good as two timed samples and a correctly diluted standard.
Open questions
- Does measuring plasma volume with a tracer change transfusion or diuretic decisions, or only describe the patient more precisely?
- How large is the error from capillary leak in sepsis and burns, where a two-point extrapolation over ten minutes is least secure?
- Can non-radioactive albumin dilution or carbon-monoxide rebreathing match a 60-day-half-life tracer without a radiopharmacy?
- Why has a biologic licensed in 1976 never been tested in a prospective outcome trial?
More in this index
Sources
- DailyMed - JEANATOPE (iodinated I 125 albumin) injection, solution - labeling and NDC listing
- Drugs@FDA - BLA 017836, JEANATOPE (Iso-Tex Diagnostics)
- Wikipedia - Iodine (125I) human albumin
- Wikipedia - Iodine-125 (decay, photon emissions, production)
- Margarson & Soni, Plasma volume measurement in septic patients using an albumin dilution technique, Intensive Care Med 2005
- Nørskov et al., Can Plasma Volume Determination in Cirrhosis Be Replaced by an Algorithm Using Body Weight and Hematocrit?, Diagnostics 2024
- Storaasli, Krieger, Friedell & Holden, The use of radioactive iodinated plasma protein in the study of blood volume, Surg Gynecol Obstet 1950
- ClinicalTrials.gov search - iodinated I-125 albumin (no registered studies)
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.