Medicine
Iopentol
Three iodine atoms per molecule are why iopentol makes vessels and ducts visible on an X-ray
What it is
Iopentol is a water-soluble radiocontrast agent built around a benzene ring carrying three iodine atoms. Each molecule (C20H28I3N3O9, molecular weight 835.2) is designed to sit in body fluids and stop X-rays, so that vessels, cavities and organs show up on an image. It is given by injection into a blood vessel or a body cavity, or swallowed. Its solutions are described as low osmolality, which the sources link to fewer adverse effects than high-osmolality agents. Regulatory approval dates are not recorded in the material available here.
What it does
The job is contrast, not therapy: iopentol does not treat anything. It fills a space — an artery, a vein, a joint capsule, a fallopian tube, the bowel — with a solution dense in iodine, and the iodine absorbs X-rays far more strongly than soft tissue does. The result is a sharper edge between the structure holding the contrast and everything around it. The packet lists arteriography, venography, CT enhancement, urography, arthrography, ERCP, hysterosalpingography and gastrointestinal studies. Route matters: it may be injected into blood vessels or body cavities, or given by mouth, depending on which structure needs to be seen. After an intravenous dose it spreads through the extracellular space and leaves unchanged, with very low binding to plasma proteins; about two hours later half of it has gone.
How it works
Target: the iodine atoms themselves. Iopentol carries three of them on an aromatic ring, and iodine's dense electron cloud is what does the work — X-ray photons are absorbed in proportion to the atoms they meet, so a structure holding an iodine solution scatters far fewer photons than the tissue beside it, and the detector records a bright or dark edge where there was none. There is no receptor, enzyme or transporter in this story: nothing is blocked or switched on, and the only questions that matter are how much iodine sits in the beam and whether the body tolerates carrying it. What the molecule's shape buys is that second question: the IUPAC name records 2,3-dihydroxypropyl and 2-hydroxy-3-methoxypropyl substituents, the compound is described as water-soluble, and the solution is low osmolality — relatively few dissolved particles per unit of iodine delivered — which the sources link to fewer adverse effects than high-osmolality agents produce. The molecule is not metabolised. It distributes in extracellular fluid, binds plasma proteins very little, and is filtered unchanged at the glomerulus, with a biological half-life of two hours and about 2% leaving in faeces.
Step by step
- Iodine is delivered — Three iodine atoms per iopentol molecule arrive in the structure being imaged, carried by a water-soluble solution injected into a vessel or body cavity, or given by mouth.
- X-rays meet iodine — Photon absorption rises with the number of dense atoms in the path, so the iodine-filled structure stops X-rays that would otherwise pass straight through soft tissue.
- The image changes — Fewer photons reach the detector behind the filled structure than behind its surroundings, and the boundary between the two becomes readable.
- Osmolality sets the cost — Because the solution is low osmolality — fewer particles per unit of iodine — the sources link it to fewer adverse effects than high-osmolality agents.
- The body clears it — Iopentol is not metabolised; it stays in extracellular fluid with very low protein binding and is filtered unchanged by the glomerulus, half gone in about two hours, roughly 2% via faeces.
What it is used for
- Arteriography and venography (imaging arteries and veins)
- CT scan enhancement
- Urography (imaging the urinary system)
- Arthrography (imaging the joints)
- ERCP and gastrointestinal studies (bile and pancreatic ducts, bowel)
- Hysterosalpingography (uterus and fallopian tubes)
What to watch for
- Nausea
- Vomiting
- Headache
- Blood pressure or heart rate that falls or rises
- Allergy-like skin reactions such as rash, usually mild
- Glottal oedema (swelling at the voice box)
- Shock
- Cardiac arrest
Interactions
- Iodine-131 used for thyroid scintigraphy — Residual iodine left in the body after iopentol competes for the same uptake pathway the radioactive isotope depends on, so imaging can be less effective if done within two to six weeks.
- Iodine-131 used to treat thyroid cancer — The same residual-iodine effect blunts the therapy, on the packet's two-to-six-week window rather than through any enzyme interaction.
- Other iodine-containing contrast media given in the same period — An additive iodine load is the mechanism the packet describes for iodine-131 interference; it gives no data on combining iodine-based agents, so the size of any extra effect is unknown.
Avoid if
- Acute inflammation in the pelvic region, when hysterosalpingography is planned — the packet records this as a contraindication for that procedure.
- Iodine-131 scintigraphy or thyroid-cancer therapy scheduled within two to six weeks — residual iodine can make the isotope less effective.
- A very large or repeated iodine load is expected — the packet documents residual body iodine after iopentol but sets no limit, so this cannot be settled from the sources.
How it was discovered
The packet gives no discovery date and names no inventor. What it does record is the molecule: C20H28I3N3O9, molecular weight 835.2, a tri-iodinated benzene ring with bis(2,3-dihydroxypropyl) amide arms and an N-acetyl-N-(2-hydroxy-3-methoxypropyl) substituent. That structure puts it in the generation of contrast agents engineered for low osmolality rather than the earlier high-osmolality salts, a design choice the sources tie directly to better toleration. ChEMBL indexes it as CHEMBL2104783. When it was first made, and by whom, is absent from this material — a patent or synthesis paper would settle it.
Approval history
Approval is the weakest part of this entry. ChEMBL lists the maximum clinical phase as 2.0 and the first approval date as unknown, and no FDA label sections were retrieved, so no indication, dose or boxed warning can be quoted from a label. That database phase sits awkwardly beside the encyclopedia's account of a completed phase III comparison against iohexol, which implies work beyond phase II. A regulatory database, or the product's own labelling, would resolve the discrepancy; ChEMBL also records no black-box warning and does not flag the compound as first-in-class.
Impact
Where it is used, the impact is practical rather than curative: it made vessels, cavities and ducts readable on X-rays, and the packet's list of procedures — arteriography, venography, urography, arthrography, ERCP, hysterosalpingography, gastrointestinal studies — shows how wide that reach was. The one head-to-head result the packet carries found image quality as high as iohexol with equal toleration. Yet ClinicalTrials.gov returns no registered studies and no systematic review matched a title search, so the modern evidence base is invisible in these sources even as the clinical uses are described in detail.
What the research shows
Thin and oddly shaped. A phase III comparison is described, pharmacokinetics are set out in some detail, and yet the registries come back empty: no registered studies, no matched systematic review, no consumer topic, and a database maximum of phase 2 with first approval unknown. The literature that would normally surround a marketed contrast agent is not visible here.
Key findings
- Iopentol produced images of similarly high quality to iohexol and was equally well tolerated.
- Biological half-life about two hours, distribution in extracellular fluid, very low plasma protein binding, no metabolism, excretion unchanged by glomerular filtration, about 2% in faeces.
- ChEMBL records a maximum clinical phase of 2.0, which sits below the phase III work the encyclopedia describes.
- ClinicalTrials.gov returned 0 registered studies and a Europe PMC title search matched no systematic reviews.
What is still unsettled
The direction of the evidence is favourable — equivalence to iohexol on image quality and toleration — but it rests on a single described trial with no numbers, no registry entry and no review to check it against. Nothing in the packet quantifies how often the common adverse effects occur, and nothing establishes which indications were formally approved anywhere. Frequency data and approval records, not more summaries, are what would move this from promising to established.
Open questions
- Where is iopentol approved, for which indications, and on what date was it first authorised? The packet records the first approval as unknown and retrieves no label.
- Why does ChEMBL cap the clinical phase at 2.0 when a completed phase III comparison against iohexol is reported?
- How often do nausea, vomiting, headache and blood-pressure or heart-rate changes actually occur? The packet gives severity for rash and rarity for glottal oedema, shock and cardiac arrest, but no rates.
- What happens when glomerular filtration is impaired, given that renal clearance is the only route the packet describes? No dose adjustment or warning appears in these sources.
More in this index
Sources
- ChEMBL compound report card: iopentol (CHEMBL2104783)
- Wikipedia: Iopentol (uses, mechanism, pharmacokinetics, adverse effects)
- Wikipedia: Iopentol (chemistry and clinical background)
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.