Medicine

Indium (111In) imciromab

Indium (111In) imciromab: the mouse antibody that made dead heart muscle visible

What it is

Indium (111In) imciromab is a diagnostic radiopharmaceutical sold as Myoscint: a fragment of a mouse monoclonal antibody, clone R11D10, that recognises cardiac myosin, joined through a DTPA chelator to the gamma-emitting isotope indium-111. It was given into a vein not to treat anything but to make irreversibly injured heart muscle light up on a gamma camera. The antibody does the targeting and the isotope supplies the signal. Marketing ended in 1993, so the product itself is historical, although the imaging principle it proved is still used in research.

What it does

Once injected, the Fab fragment circulates for hours to days, distributing through roughly five litres of plasma and clearing at about 136 mL per hour. Wherever a cardiomyocyte has lost the integrity of its surface membrane, antibody leaves the capillary bed, enters the cell and attaches to myosin that is normally sealed inside. Antibody that finds no such target is carried away and broken down, with highest retention in marrow and liver and highest concentration in the kidneys. Images were therefore acquired a day or two after injection, once blood-pool background had fallen far enough for focal cardiac uptake to stand out. Readers treated the result as a map of necrosis: whether an infarct was present, where it sat, how large it was, and whether damage was focal, as in infarction, or patchy and diffuse, as in myocarditis or transplant rejection.

How it works

The target is the heavy chain of cardiac myosin, the motor protein forming the thick filament of the sarcomere. Myosin is an intracellular antigen: in an intact myocyte it is invisible to anything circulating in blood. Irreversible injury, whether from ischaemia, inflammation, anthracycline toxicity or mechanical trauma, destroys the sarcolemma, the cell can no longer exclude large proteins, and myosin becomes reachable from the interstitial space. The R11D10 Fab binds exposed myosin with an affinity of about 5 × 10^8 M^-1, and that bond holds the indium chelate inside dying tissue while unbound tracer washes out. Affinity is not a detail: in reperfused dog infarcts a low-affinity antimyosin Fab produced an infarct-to-blood ratio of 0.85, indistinguishable from a nonspecific Fab, and no infarct was visible, while two high-affinity Fabs imaged every infarct by five hours. Detection is doubly specific, for myosin and for tight enough binding. Trapped isotope decays over days with the half-life and photon energy a gamma camera is built for. Because the whole chain begins with membrane rupture, uptake reports cell death rather than ischaemia, which is why the tracer could separate infarction from angina yet could not tell cardiac necrosis from skeletal muscle necrosis.

Step by step

What it is used for

What to watch for

Interactions

Avoid if

How it was discovered

The idea came from Edgar Haber's laboratory at Massachusetts General Hospital, where Ban-An Khaw, John T. Fallon, H. William Strauss and Haber wanted to mark dying heart cells rather than blood flow. In 1980 they reported in Science that F(ab')2 fragments against canine cardiac myosin, first labelled with iodine-131, localised in experimental infarcts in dogs; because iodine emissions suited a gamma camera poorly, they coupled the bifunctional chelator DTPA to the fragments and loaded it with indium-111 while antigen binding survived. In 1984 Khaw and colleagues raised the monoclonal antibody R11D10 against human cardiac myosin, which cross-reacted with dog myosin and became the parent molecule of the commercial product.

Approval history

Centocor, a biotechnology company in Malvern, Pennsylvania, carried R11D10 forward as a Fab fragment and named the finished radiopharmaceutical Myoscint. Clinical work ran through European cardiology units in the late 1980s: Jain, Lahiri and Raftery reported 119 consecutive patients from a district general hospital coronary care unit in the BMJ in 1990, and Centocor Europe in Leiden supplied material to transplant and cardiomyopathy studies published in 1991 and 1992. A Japanese multicentre programme imaged 456 patients with 74 MBq of activity on 0.5 mg of Fab and tested 393 of them for anti-mouse antibodies. The encyclopedia record states that the product was withdrawn in 1993, and no approval for Myoscint or imciromab appears in FDA's public drug databases.

Impact

Myoscint proved a principle that outlived it: a labelled antibody could report a molecular event inside the heart, loss of membrane integrity, rather than anatomy or perfusion. That idea seeded a generation of necrosis and apoptosis tracers, among them technetium-99m glucarate, annexin-V imaging of exposed phosphatidylserine, and Khaw's antimyosin-coated liposomes that sealed damaged cardiocyte membranes in 1995. Its limits were equally instructive: images needed a day or two because antibody cleared slowly, anti-mouse antibodies formed in 2.8% of patients, and specificity in myocarditis was poor. Khaw's own 1999 review conceded that the delay was the decisive flaw and looked to technetium-99m glucarate for the early-diagnosis role antimyosin could not fill.

What the research shows

The evidence base is a set of diagnostic-accuracy studies from the 1980s and 1990s: prospective series in coronary care units, biopsy-correlated myocarditis cohorts, transplant and cardiotoxicity series, and dog infarct experiments. There were no randomised trials, no registered studies remain, and the product is off the market, so nothing can be added to that record.

Key findings

What is still unsettled

No randomised comparison was ever run against another imaging strategy, and the record of withdrawal in 1993 gives no reason for it, so whether commercial pressure or the immunogenicity findings ended the product is not recoverable from the literature. The investigators who measured anti-mouse antibodies left open whether they would matter clinically on a second exposure. All performance figures come from 1980s and 1990s cameras, interpretation conventions and biopsy standards, and cannot be transplanted onto modern practice.

Open questions

More in this index

Sources

RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.