Medicine · Positron Emitting Activity [MoA] · Radioactive Diagnostic Agent
Fluciclovine F-18
A synthetic amino acid carrying fluorine-18, read by PET to map suspected prostate cancer recurrence
What it is
Fluciclovine F 18 is a synthetic amino acid — 1-amino-3-(18F)fluorocyclobutane-1-carboxylic acid, C5H8FNO2, molecular weight 132.12 — with a fluorine-18 atom on a cyclobutane ring, marketed as Axumin by Blue Earth Diagnostics, Ltd. It is a radioactive diagnostic agent drawn up for intravenous injection before a PET scan, not a therapy: it carries no cytotoxic payload and has no pharmacological job beyond being carried into cells by amino acid transporters and announcing where it went. ChEMBL records maximum phase 4 and first approval in 2016.
What it does
Given intravenously, fluciclovine F 18 spreads widely: 14% of administered activity goes to the liver, 12% to red bone marrow, 7% to lung, 4% to myocardium and 3% to pancreas, with a later shift into skeletal muscle. Its function in the labeled setting is to make transporter-rich tissue conspicuous against that background during the few minutes when the ratio is best — contrast peaks between 4 and 10 minutes after injection, and mean tumor uptake is already 61% lower at 90 minutes. Excretion is slow and largely non-renal: 3% of radioactivity appears in urine across four hours and 5% across 24. In men whose PSA has risen after prior prostate cancer treatment, that early, short-lived contrast is the whole clinical product — a PET map of where amino acid transport is running hot, timed to a scan rather than to a course of treatment.
How it works
The molecular target is not a receptor but a pair of amino acid transporters, LAT-1 and ASCT2, both upregulated in prostate cancer cells. Fluciclovine F 18 is a synthetic amino acid, and these transporters handle it the way they handle their natural cargo, carrying it across the cell membrane; because they sit at higher density on malignant prostate cells than on surrounding normal tissue, the agent accumulates to a greater extent there. Fluorine-18 does the reporting: the positron it emits is what the PET camera reconstructs into an image, so brightness on the scan reads out transporter-mediated influx rather than hormone receptor status, perfusion, or glucose metabolism. Two features of the kinetics matter. First, the contrast is perishable — the tumor-to-normal ratio is highest 4 to 10 minutes after injection, and mean tumor uptake drops 61% by 90 minutes, so tracer is leaving or being exported nearly as fast as it arrives. Second, the background is soft-tissue heavy and urinary light: liver, marrow, lung and myocardium hold activity, while only 3% of the dose reaches urine in four hours and 5% in 24, leaving little renal clearance to strip background away. Other substrates of LAT-1 and ASCT2 are, by definition, amino acids and amino-acid-like molecules; uptake here is assigned by transporter class, and no named competing substrate is assayed against fluciclovine in the label.
Step by step
- Transporter recognition at the membrane — LAT-1 and ASCT2, upregulated on prostate cancer cells, take up fluciclovine F 18 as they would an amino acid and move it across the cell membrane.
- Preferential intracellular accumulation — Because transporter density is higher on malignant prostate cells than on surrounding normal tissue, tracer concentration is greater inside tumor.
- Positron emission and detection — The fluorine-18 label decays by positron emission, and the PET camera reconstructs the resulting annihilation signal into a three-dimensional map of tracer location.
- The narrow contrast window — Tumor-to-normal contrast is highest 4 to 10 minutes after injection, and mean tumor uptake falls 61% by 90 minutes, so acquisition must fall inside an early window.
- Retained soft-tissue background — Liver (14% of administered activity), red bone marrow (12%), lung (7%) and myocardium (4%) hold activity while urinary excretion removes only 3% over four hours and 5% over 24.
What it is used for
- Suspected prostate cancer recurrence with elevated blood PSA after prior treatment
- Repeat PET imaging in the same patient
- Registered PET imaging research
Dosing as the label states it
The label states: Use appropriate radiation safety handling measures ( 2.1 ). Aseptically withdraw Axumin from its container and administer 370 MBq (10 mCi) as a bolus intravenous injection. ( 2.2 ). Initiate imaging 3 minutes to 5 minutes after administration. Scanning should start from mid-thigh and proceed to base of skull, with a total scan time of approximately 20 minutes to 30 minutes ( 2.4 ). The (radiation absorbed) effective dose associated with 370 MBq (10 mCi) of injected activity of Axumin is approximately 8 mSv (0.8 rem) in an adult ( 2.6 ). 2.1 Radiation Safety - Drug Handling Axumin is a radioactive drug and should be handled with appropriate safety measures to minimize radiation exposure during administration [see Warnings and Precautions ( 5.3 ) ]. Use waterproof gloves and effective shielding, including syringe shields, when handling and administering Axumin.
What to watch for
- Injection site pain
- Injection site erythema
- Dysgeusia (altered taste)
- Radiation exposure of liver, red bone marrow, lung and myocardium from fluorine-18 decay
- Tumor signal fading by 90 minutes, when mean uptake is 61% below peak
Interactions
- Other substrates of LAT-1 and ASCT2 — Uptake runs through transporter-mediated entry, so other amino acids and amino-acid-like molecules handled by the same carriers are the class that shares this route; the label assigns uptake by transporter class rather than by competition assay.
- A second radiotracer imaged in the same session — The label describes a single intravenous administration whose contrast peaks 4 to 10 minutes after injection and is 61% gone by 90 minutes, so a second agent shares one narrow detection window.
- Repeat administration of fluciclovine F 18 itself — 50 subjects in the trial database received up to five administrations, and distribution shifts toward skeletal muscle with increasing time after dosing.
Avoid if
- PSA is not elevated — the labeled indication is keyed to a rising blood PSA after prior treatment.
- The question is initial detection or first-line staging — the labeled use is suspected recurrence after prior treatment.
- The patient is outside the labeled population of men with suspected recurrence; no other population carries an indication.
How it was discovered
Fluciclovine is a designed molecule rather than a harvested natural product: a cyclobutane ring bearing both an amino group and a carboxylic acid, tagged with fluorine-18, giving C5H8FNO2 and a molecular weight of 132.12. The chemistry solves a delivery problem — a small frame with the amino and acid groups that LAT-1 and ASCT2 will accept as cargo, so a positron emitter can be carried into the cells whose transporters are upregulated. ChEMBL indexes it as CHEMBL254468 with a mechanism listed as diagnostic agent and a maximum phase of 4.
Approval history
ChEMBL records first approval in 2016, under the brand Axumin from Blue Earth Diagnostics, Ltd, whose US reporting line the label prints as 1-855-AXUMIN1. The approved claim is deliberately narrow: positron emission tomography in men with suspected prostate cancer recurrence based on elevated blood PSA following prior treatment. The clinical database behind it holds 877 subjects, 797 of them men diagnosed with prostate cancer; most received a single administration and 50 received up to five. The label itself cautions that adverse-reaction rates from trials run under widely varying conditions cannot be compared directly with those of another drug.
Impact
Axumin tied a PET image to a blood test: a rising PSA triggers the scan, and the readout is amino acid transport rather than receptor expression. The label's own numbers describe how perishable that readout is — best contrast at 4 to 10 minutes, 61% of mean tumor uptake gone by 90 — which makes timing a clinical variable rather than a technical footnote. Seventy-one studies registered on ClinicalTrials.gov carry the compound's name, the footprint of a single narrow 2016 indication that became a standing research platform.
What the research shows
Active: 71 studies are registered on ClinicalTrials.gov under fluciclovine F-18, and ChEMBL lists the compound at maximum phase 4 with first approval in 2016.
Key findings
- Tumor-to-normal contrast is highest 4 to 10 minutes after injection, with a 61% reduction in mean tumor uptake by 90 minutes.
- Administered activity distributes to liver (14%), red bone marrow (12%), lung (7%), myocardium (4%) and pancreas (3%), with later shift into skeletal muscle; 3% of radioactivity is excreted in urine over four hours and 5% over 24.
- The trial database holds 877 subjects, 797 of them men with prostate cancer; most received one administration and 50 received up to five.
What is still unsettled
The gathered label characterizes transport, distribution and washout, not detection rates, stage migration, or whether a scan changed management. With liver at 14% and red bone marrow at 12% of administered activity and only 5% urinary excretion by 24 hours, how much residual soft-tissue activity limits lesion reading in an individual patient is not quantified. Repeat dosing to five administrations is recorded but not characterized for its effect on image interpretation.
Open questions
- Which other amino acid transporter substrates compete with fluciclovine at LAT-1 and ASCT2 in vivo, and at what concentration would that competition visibly change a scan?
- What happens to interpretation when a second fluorine-18 radiotracer is given in the same session, given that contrast peaks 4 to 10 minutes after injection and mean tumor uptake has fallen 61% by 90 minutes?
- Do the fixed soft-tissue deposits — liver 14%, red bone marrow 12% of administered activity — set a practical floor on detectability in the pelvis, given that only 5% of the dose clears in urine by 24 hours?
Drug class
Related
- Copper Oxodotreotide Cu-64
- Florbetaben F-18
- Florbetapir F-18
- Flotufolastat F-18
- Fluoroestradiol F-18
- Flurpiridaz F-18
Sources
- DailyMed label — Axumin (fluciclovine F 18)
- ChEMBL compound report card CHEMBL254468
- ClinicalTrials.gov — fluciclovine F-18 studies
- Wikipedia — Fluciclovine (18F)
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.