Medicine
Eledoisin
An octopus salivary peptide that raised tear flow 250% in dry eyes, without approval
What it is
Eledoisin is an eleven-amino-acid peptide from the posterior salivary glands of Eledone moschata, a Mediterranean octopus that delivers the secretion to its prey. Its sequence, pGlu-Pro-Ser-Lys-Asp-Ala-Phe-Ile-Gly-Leu-Met-NH2, ends in the Phe-X-Gly-Leu-Met-amide tail shared by every tachykinin, and in 1962 it became the first tachykinin to be sequenced. It holds an INN but no approval: no FDA label exists, ChEMBL records a maximum clinical phase of 2, and ClinicalTrials.gov lists no study. Human use has been almost entirely as an experimental eye drop intended to raise tear output.
What it does
Eledoisin acts wherever tachykinin receptors sit: vascular endothelium, the smooth muscle of gut, bladder, bronchi and vas deferens, and exocrine glands including the lacrimal and submandibular glands. Applied to the eye, its intended job is narrow — to make the lacrimal gland and accessory glands put more fluid onto the surface, so a dry cornea is rewetted and the tear film holds together longer. That rationale sits behind every human study of it. Whether it works by acting on the gland directly is doubtful: in rabbits with a cannulated lacrimal duct, topical eledoisin raised secretion only in eyes that still had sensation, and prior proparacaine abolished the effect, pointing to a corneal sensory reflex rather than gland stimulation. In people, fluorophotometry after topical eledoisin measured a 250% rise in tear flow in severely dry eyes, so some link in that chain does operate.
How it works
Molecular target first: the neurokinin receptors NK1 (TACR1), NK2 (TACR2) and NK3 (TACR3), G-protein-coupled receptors that natural tachykinins engage through their shared C-terminal pentapeptide. Eledoisin's own record shows how unconventionally it behaves. Radiolabelled eledoisin bound guinea-pig lung membranes with an equilibrium dissociation constant of 1.98 nM, and competition orders there identified NK1 sites. At recombinant human NK3 receptors, however, eledoisin generated inositol phosphates with EC50 values of 5.7 and 6.6 nM and drove calcium influx at 0.22 nM, against a binding IC50 of 96 nM — potency at NK3 well beyond what its NK1 displacement assay, complete only at 10 micromolar, would predict. Sequence explains part of this. The invariant Phe7 and the C-terminal message domain are needed for activation, while the variable N-terminal address domain steers subtype preference, and eledoisin's N-terminus is unusual enough that its selectivity shifts between tissues and species. Downstream, receptor occupation raises inositol phosphates and intracellular calcium, contracts smooth muscle, dilates vessels through the endothelium and drives glandular fluid and protein output. In the tear film that means more fluid, though how much arrives by reflex sensory activation rather than direct glandular stimulation remains unresolved.
Step by step
- Engage neurokinin receptors — The C-terminal FXGLM-amide tail binds NK1, NK2 and NK3. Radiolabelled eledoisin labelled guinea-pig lung NK1 sites at a Kd of 1.98 nM; at cloned human NK3 it drove calcium influx with an EC50 of 0.22 nM.
- Raise inositol phosphates and calcium — Receptor activation increased inositol phosphate generation in NK3-expressing cells with EC50 values of 5.7 and 6.6 nM, the second-messenger step that mobilises intracellular calcium.
- Activate secretory and vascular tissue — Calcium signalling contracts smooth muscle, relaxes vascular tone and drives fluid and protein output from exocrine glands, including lacrimal and submandibular tissue.
- Recruit the corneal sensory reflex — In rabbits with a cannulated lacrimal duct, the tear increase appeared only in sensate eyes; proparacaine, a topical anesthetic, abolished it.
- Raise measured tear output — Fluorophotometry in 40 people found tear volume up 87% and tear flow up 250% in severe dry eye one hour after instillation, with the effect lasting to two hours.
What it is used for
- Dry eye disease (keratoconjunctivitis sicca)
- Severe keratoconjunctivitis sicca, including Sjögren syndrome
- Filamentary keratitis
- Dry eye caused by preserved glaucoma drops
- Peripheral vasodilation and hypotension
- Salivary secretion stimulation
What to watch for
- Shorter tear break-up time than artificial tears, meaning the film destabilised sooner
- Eye discomfort or irritation after instillation
- Eye discharge
- Reflex lacrimation and overflow tearing from sensory nerve stimulation
- Conjunctival redness from vasodilation
- Hypotension and flushing if enough peptide reaches the circulation
- Local allergic reaction to the peptide
Interactions
- Topical ocular anesthetics such as proparacaine or oxybuprocaine — They block the corneal sensory reflex that produced eledoisin's tear increase in rabbits; in anesthetised eyes the secretory response disappeared.
- Neutral endopeptidase inhibitors such as sacubitril, and ACE inhibitors — Both enzymes cleave tachykinins; phosphoramidon, a neutral endopeptidase inhibitor, raised specific binding of radiolabelled eledoisin two- to threefold in guinea-pig lung membranes by slowing peptide breakdown.
- NK1 receptor antagonists such as aprepitant or rolapitant — They occupy the same NK1 receptor, so blockade competes directly with eledoisin's agonist action at that subtype.
- Preserved glaucoma drops containing benzalkonium chloride — Additive ocular-surface toxicity; the 40-patient eledoisin trial deliberately enrolled patients whose dryness came from chronic benzalkonium exposure.
- Anticholinergic and sedating antihistamine drugs that dry the eye — They suppress muscarinic fluid secretion at the lacrimal gland, working against the secretagogue effect eledoisin is given for.
Avoid if
- A previous allergic reaction to eledoisin or another peptide eye drop — no label sets contraindications, and repeated exposure to a foreign peptide can sensitise the conjunctiva.
- An active eye infection or a recently operated eye — no study has tested eledoisin in either setting, and a secretion-stimulating drop does not treat infection.
- Contact lens wear at the time of instillation — lens compatibility has never been studied for this peptide.
- Concurrent topical anesthesia — the sensory reflex that the tear response depends on is blocked.
How it was discovered
Vittorio Erspamer and Anastasi isolated eledoisin in 1962 from the posterior salivary glands of Eledone moschata and published its structure and pharmacology in Experientia. It was the first tachykinin found in an invertebrate and, by later reviewers' account, the first tachykinin to be sequenced — before substance P's sequence was known, so the family resemblance went unrecognised at first. The two authors did notice that it contracted mammalian smooth muscle much as substance P did. A 2003 NMR study found the peptide extended in water and helical across residues K4 to M11 when bound to a membrane-mimicking micelle.
Approval history
No medicines regulator has approved eledoisin. There is no FDA label; its ChEMBL record stops at phase 2 with no first-approval date, and KEGG files it as an INN with two stated uses, lacrimal secretion stimulant and vasodilator, without a national product entry. Ophthalmologists used it anyway. Bietti introduced it for eye disease, a 1975 German report described it in keratoconjunctivitis sicca, a 1985 paper called it a successful concept in filamentary keratitis, and a randomised study at Heidelberg, Cologne and Ulm reported superiority in severe sicca in 1988. Italian clinicians were still publishing combination-drop trials in 2013.
Impact
Eledoisin gave the tachykinin family its template. The Phe-X-Gly-Leu-Met-amide tail it shares with substance P, neurokinin A and neurokinin B became the defining signature of the group, and its odd selectivity — high-affinity NK1 binding in guinea-pig lung, potent NK3 agonism at cloned human receptors — helped show how much receptor preference depends on the N-terminal address region rather than the conserved tail. Chimeric NK1/NK3 receptor experiments in 1996 used eledoisin among the natural ligands that mapped that behaviour. As a medicine its reach was smaller: a niche tear secretagogue, later displaced by cyclosporine, lifitegrast and diquafosol, while NK1 antagonists such as aprepitant pushed the same receptor the other way.
What the research shows
Human evidence is old, small and concentrated in European ophthalmology: single-centre and multicentre studies from 1975 to 2013, one 2022 network meta-analysis that pooled the eye-drop trials, and no registered study anywhere. No modern placebo-controlled trial of eledoisin as a single agent exists in the retrieved record.
Key findings
- Topical eledoisin raised tear flow by 250% and tear volume by 87% in severely dry eyes one hour after instillation, with effects lasting two hours
- Eledoisin ranked first of twelve interventions for Schirmer score, adding 2.28 mm over artificial tears (95% CI 0.14 to 4.42; SUCRA 91.1%)
- The same analysis found eledoisin shortened tear break-up time by 2.85 seconds relative to artificial tears (95% CI -5.01 to -0.68)
- A combination eledoisin, carnitine, taurine and hyaluronate drop cut symptom severity by about half after 15 days
- Topical eledoisin did not stimulate the lacrimal gland directly in rabbits; the effect vanished once the eye was anesthetised
What is still unsettled
Whether the human tear increase comes from glandular receptors or from a corneal sensory reflex is unsettled, and the 1990 rabbit work favours the reflex. The 2013 trial used a four-ingredient drop, so its symptom benefit cannot be assigned to eledoisin. The network meta-analysis rated its own comparisons low or very low certainty, and no pharmacokinetic data describe how long a topically applied undecapeptide survives on the ocular surface.
Open questions
- Does eledoisin act on lacrimal acinar neurokinin receptors directly, or only through corneal sensory nerves?
- Which receptor subtype — NK1, NK3, or a mixture — carries the human tear response?
- Can a modern placebo-controlled trial reproduce the 1991 fluorophotometry result with eledoisin alone?
- Why does tear production rise while tear film stability falls?
More in this index
Sources
- KEGG DRUG entry for eledoisin (INN), listing lacrimal secretion stimulant and vasodilator efficacy
- MedlinePlus Medical Encyclopedia: Dry eye syndrome
- Short-term efficacy and safety of tear promotion eye drops for dry eye disease: systematic review and network meta-analysis (Cornea, 2022)
- Effect of eledoisin on tear volume and tear flow in humans as assessed by fluorophotometry (Graefe's Archive, 1991)
- ChEMBL molecule record CHEMBL373569 and its bioactivity entries
- PubChem CID 10328936 (Eledoisin): formula, mass, synonyms and development phase
- Tachykinins: neuropeptides that are ancient, diverse, widespread and functionally pleiotropic (Frontiers in Neuroscience, 2019)
- ClinicalTrials.gov search for eledoisin, returning no registered studies
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.