Medicine
Biciromab
Biciromab aimed at a fibrin β-chain end exposed only after thrombin cuts fibrinopeptide B
What it is
Biciromab is the international nonproprietary name for the Fab' fragment of T2G1S, a mouse monoclonal antibody raised against the amino-terminal end of the fibrin β chain. Coupled to the gamma-emitting isotope indium-111, it was developed by Centocor as FibriScint, a radiopharmaceutical meant to make blood clots visible on a gamma camera rather than to treat anything. Its CAS number is 138783-13-8. A technetium-99m-labeled version of the same antibody also appeared under the biciromab name. It was never licensed: ChEMBL records a maximum phase of 2 and no first-approval date.
What it does
Biciromab answered one question on a gamma camera: is there a fresh clot, and where? Injected into a vein, the labeled fragment circulates, and the portion that meets newly deposited fibrin sticks to it. Because the antibody's epitope is buried on circulating fibrinogen, unbound tracer clears and the clot stands out as a hot spot on planar or tomographic images. For the person being examined this meant an injection and repeated passes under a camera over hours, without the contrast injection of a venogram; a 1991 review put diagnostic accuracy near 90 percent and stressed that both legs, above and below the knee, could be read in one session. Later series were less flattering where clots were old or arterial: in 18 people with chronic arterial thrombi, 44 percent of antifibrin scans showed uptake against 94 percent for indium-111 platelets.
How it works
The molecular target is the amino-terminal end of the β chain of fibrin II, the fibrin left after thrombin has removed fibrinopeptide B. That terminus is buried in intact fibrinogen and becomes accessible only once thrombin cuts the molecule, so the antibody separates fibrin that has just been laid down from the soluble fibrinogen circulating at far higher concentration. T2G1S, the parent clone, was raised against a synthetic copy of that seven-residue terminus. Biciromab keeps only the Fab' arm: monovalent, one binding site, no Fc tail, so it leaves the blood faster than an intact immunoglobulin and draws a smaller anti-mouse response. Indium-111 carried on the protein emits gamma rays that escape the body, so bound fragment is detected from outside while unbound fragment is cleared. The design is self-limiting in time. As a thrombus matures and plasmin nibbles its fibrin, the β-chain terminus disappears; in dogs, T2G1S signal was strongest in three-hour-old thrombi and fell behind a competitor antibody that reads a later, plasmin-generated neoepitope in three-day-old clots, which is why the agent was framed as a test for acute thrombosis rather than for clot burden in general.
Step by step
- Thrombin trims fibrinogen — Thrombin cleaves fibrinopeptides A and B from fibrinogen, and the removal of fibrinopeptide B leaves a new amino-terminal sequence on the β chain.
- A neoepitope appears — That terminus sits hidden inside intact fibrinogen, so it exists only on fibrin that has just polymerised, which makes it a marker of fresh clot rather than of clotting potential.
- The Fab' binds — Biciromab carries one T2G1S binding site per molecule and no Fc region, so it attaches to exposed fibrin β-chain ends without cross-linking strands and without the slow clearance of whole IgG.
- Indium-111 reports the position — The chelated isotope emits gamma photons that pass through tissue, so a camera outside the body sees focal activity wherever fragment has accumulated and background where it has not.
- The signal expires — Maturation and plasmin digestion strip the β-chain terminus, so uptake fades as a clot ages and the technique reads acute thrombosis rather than the older clots most people present with.
What it is used for
- Suspected acute deep vein thrombosis
- Chronic arterial thrombosis
- Thromboembolism imaging by radioimmunoscintigraphy
What to watch for
- A chronic arterial thrombus that does not accumulate enough tracer to be seen
- Blood-pool activity in large vessels read as clot
- Human anti-mouse antibody response to the murine fragment
- Weaker clot uptake in people already given heparin
- Radiation exposure from the indium-111 label
Interactions
- Heparin — In dogs with one- and three-day-old thrombi, heparinised animals showed less T2G1s uptake relative to a comparator antifibrin antibody, with GC4/T2G1s ratios of 2.3 and 2.9 against 1.1 and 1.9 in untreated animals, consistent with anticoagulation limiting fresh fibrin deposition at the clot surface.
- Thrombolytic drugs such as plasminogen activators — Plasmin digests fibrin and destroys the β-chain amino terminus that T2G1s recognises, the same loss that let a plasmin-neoepitope antibody outperform it in older canine thrombi.
- Earlier exposure to mouse antibodies — Pre-existing or induced human anti-mouse antibodies can occupy the Fab' binding site or speed its clearance, reducing the fraction that reaches fibrin.
- Technetium-99m human serum albumin blood-pool agents — These were used alongside antifibrin scintigraphy to subtract intravascular activity; without subtraction, tracer held in major veins adds background that mimics clot.
Avoid if
- Known hypersensitivity to mouse proteins — the fragment is of murine origin, so an anti-mouse antibody response can target it.
- Pregnancy or breastfeeding — a radionuclide-labeled agent with no approved labeling and no published pregnancy data, the drug information listing the pregnancy category as not applicable.
- Suspicion of an aged or chronic thrombus — the β-chain epitope is largely gone once fibrin matures or plasmin digests it, so absent uptake would not exclude clot.
How it was discovered
The antibody started as a laboratory reagent. In 1984 Kudryk and colleagues described a mouse monoclonal antibody specific for the NH2-terminal region of fibrin, the T2G1S clone, following the strategy Hui had used a year earlier to raise 59D8 against a seven-residue mimic of the fibrin β-chain terminus. Centocor, a Malvern, Pennsylvania biotechnology company, took the clone, reduced it to a Fab' fragment and coupled it to indium-111, calling the imaging agent FibriScint.
Approval history
It never received one. Centocor had filed United States product license applications for two antibody imaging agents, Myoscint and Fibriscint, and on 16 June 1993 withdrew both after an independent auditor found deficiencies that the company itself reported to the FDA. Myoscint's problems looked fixable by reanalysing existing data; for Fibriscint a spokesperson said additional clinical work would be required. ChEMBL lists biciromab at maximum phase 2 with no first-approval date.
Impact
Biciromab's contribution was conceptual. T2G1S and 59D8, both aimed at the fibrin β-chain amino terminus, became what a 2022 review calls a gold standard for fibrin targeting, and the same neoepitope logic runs through later fibrin-specific imaging and therapeutic constructs. The clinical lesson was narrower: a probe that reads only newly deposited fibrin images a moving target, which is why antibodies against plasmin-exposed epitopes were proposed for the older clots patients actually present with. Biciromab left no marketed product.
What the research shows
Development stopped at phase 2, and no study of biciromab is registered on ClinicalTrials.gov. What survives is a set of canine experiments and single-centre imaging series published between 1988 and 1995, testing the indium-111 and technetium-99m forms of the T2G1S fragment against contrast venography or against indium-111 platelet imaging.
Key findings
- Technetium-99m T2G1s Fab' concentrated in experimental arterial thrombi, with a thrombus-to-blood ratio of 4.24 ± 2.58 against 0.65 ± 0.46 for control artery, and cleared from blood with a half-life of 121 ± 23 minutes.
- In people with chronic arterial thrombi, antifibrin imaging found far fewer lesions than indium-111 platelet imaging: 44 percent versus 94 percent graded positive on planar images, and a lower tomographic target-to-background ratio (1.8 ± 1.0 versus 2.5 ± 1.4).
- Subtracting the immediate blood-pool image from the delayed scan raised accuracy for deep vein thrombosis from 79.1 to 90.7 percent area under the ROC curve among readers whose displays were not pre-optimised.
- T2G1S uptake was highest in three-hour-old canine thrombi, while a competitor antibody against a plasmin-generated neoepitope (GC4) reached 1.9 times its concentration in three-day-old clots, reversing the ranking as thrombi aged.
What is still unsettled
The two indium-111 patient series that supply the best human accuracy figures describe their agent only as an antifibrin Fab', while a 1991 review of the programme attributes the indium-111 clinical antibody to the sibling clone 59D8, not T2G1S. How much of that accuracy belongs to biciromab itself is therefore unresolved, and no accessible abstract reports anti-mouse antibody titres or a head-to-head comparison of the indium-111 T2G1S preparation against venography.
Open questions
- Whether the June 1993 withdrawal reflected documentation deficiencies alone or an underlying limit of a probe that images only hours-old fibrin; the regulatory review file would settle it.
- What anti-mouse antibody titres developed in the patients who received the murine fragment, and whether a second administration was ever feasible.
- Whether switching the same clone to technetium-99m, a generator-produced isotope, improved image quality over indium-111, since no direct comparison in humans was published.
More in this index
Sources
- Wikipedia: Indium (111In) biciromab
- ChEMBL: BICIROMAB, CHEMBL2108410
- Schaible & Alavi, Seminars in Nuclear Medicine 1991: antifibrin scintigraphy in acute deep venous thrombosis
- 2022 review: Engineered Molecular Therapeutics Targeting Fibrin and the Coagulation System
- Jung et al., Radiology 1989: deep vein thrombosis diagnosed with indium-111 antifibrin antibodies
- De Faucal et al., Journal of Nuclear Medicine 1991: indium-111 antifibrin antibody in 44 patients
- Stratton et al., Journal of Nuclear Medicine 1994: arterial thrombus imaging with technetium-99m T2G1s
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.