Medicine
Bentiromide
Bentiromide was a swallowed peptide probe that made pancreatic chymotrypsin measurable in urine
What it is
Bentiromide is not a treatment. It is a synthetic peptide — N-benzoyl-L-tyrosyl-p-aminobenzoic acid, formula C23H20N2O5, molecular weight 404.4 — swallowed as a single dose so that a doctor can see what the pancreas does with it. The molecule carries a benzoyl cap, a tyrosine and a p-aminobenzoic acid tail; the tyrosyl–PABA bond is the part pancreatic chymotrypsin cuts. Adria Laboratories sold it as Chymex. The U.S. Food and Drug Administration approved it in 1983, and the product was withdrawn from the U.S. market in October 1996; it is not available in the United States or Canada.
What it does
Swallowed on an empty stomach, bentiromide passes through the stomach and arrives in the duodenum, where pancreatic juice is delivered. There, chymotrypsin — a protease that normally digests dietary protein — hydrolyses the tyrosyl–PABA bond and sets p-aminobenzoic acid free. The freed PABA is absorbed across the small-intestinal mucosa, circulates in blood and is excreted by the kidneys, partly as metabolites; a share of it appears in urine. Collecting urine for six hours after a dose and measuring the arylamine recovered therefore reports, indirectly, how much active chymotrypsin reached the gut. Doctors used that number to screen for exocrine pancreatic insufficiency in chronic pancreatitis and cystic fibrosis, and to check whether replacement enzyme capsules were restoring detectable chymotrypsin activity. The result depends on absorption and kidney clearance as much as on the pancreas, which is why it was a screening test rather than a measurement of pancreatic reserve.
How it works
Target: pancreatic chymotrypsin, the serine protease that cuts peptide bonds on the carboxyl side of aromatic residues. Bentiromide was built around that preference. Its central tyrosine supplies the aromatic side chain that chymotrypsin recognises in its binding pocket; the benzoyl group caps the other end of the peptide so that gut peptidases cannot nibble it from the front; and the p-aminobenzoic acid at the far end is a reporter that is easy to measure as an arylamine. When chymotrypsin cuts the tyrosyl–PABA bond, PABA is released in the duodenum, absorbed into the blood and cleared by the kidney, partly after metabolic conversion. Urinary recovery over a fixed window is therefore proportional to the chymotrypsin activity delivered to the upper small bowel, and falls when the pancreas secretes less enzyme. The design also admits false signals. Intestinal brush-border enzymes with chymotrypsin-like activity can cleave the same bond, and any arylamine reaching the assay adds to the reading. A plasma version measured PABA at 90 minutes to shorten the wait, and a PABA excretion index — PABA from the peptide divided by PABA from an equimolar free dose — was devised to correct for differences in absorption and renal clearance.
Step by step
- Swallow the probe — A single oral dose of N-benzoyl-L-tyrosyl-PABA reaches the duodenum largely intact, because the benzoyl cap blocks digestion from the front of the peptide.
- Chymotrypsin cuts — Pancreatic chymotrypsin hydrolyses the bond between the tyrosine and the p-aminobenzoic acid, releasing free PABA into the duodenal juice.
- PABA is absorbed — Free PABA crosses the small-intestinal mucosa into the blood; how much gets through depends on mucosal integrity, not only on the pancreas.
- The kidney reports — PABA and its metabolites appear in urine, so recovery over six hours stands in for the chymotrypsin delivered to the gut.
- The number is interpreted — Low recovery suggests exocrine pancreatic insufficiency, but kidney, liver or intestinal disease can lower it without any pancreatic disease.
What it is used for
- Screening for exocrine pancreatic insufficiency
- Monitoring supplemental pancreatic enzyme therapy
- Cystic fibrosis with pancreatic involvement
- Separating pancreatic from non-pancreatic diarrhoea or steatorrhoea
Dosing as the label states it
The label states a single oral dose, after which all urine is collected for six hours; the total volume is measured and a sample examined, and the test may be repeated after seven days. It gives no milligram amount, and the U.S. product was withdrawn from the market in October 1996.
What to watch for
- Diarrhoea
- Headache
- Nausea and vomiting
- Gas
- Weakness
- Shortness of breath or troubled breathing
Interactions
- Thiazide diuretics such as chlortalidone — Thiazides are metabolised to arylamines, the same class of compound the assay measures, so they raise the percentage of PABA recovered and invalidate the result.
- Pancreatic enzyme supplements — Exogenous chymotrypsin digests the swallowed peptide before the patient's own pancreas can, adding PABA and masking a failing gland; supplements were stopped three days before testing.
- Chloramphenicol — The antibiotic is an arylamine, so giving it during the test produces falsely elevated urinary PABA.
- Paracetamol (acetaminophen) — Paracetamol is an aromatic amine read by the same arylamine chemistry; its product information warns that it interferes with pancreatic function testing using bentiromide.
- Other arylamine-forming drugs — The assay measures arylamines generally rather than PABA alone, so any drug whose metabolites are arylamines carries the same additive risk that invalidates thiazide use.
Avoid if
- Kidney disease — reduced clearance of PABA distorts urinary recovery and produces a false result.
- Severe liver disease — the consumer labeling warns that severe liver disease can make the test result false.
- Disease of the stomach or intestines — poor absorption lowers PABA recovery for reasons unrelated to the pancreas.
- Children under 6 years — studies covered only older children and adults, so no comparison exists for this age group.
How it was discovered
Bentiromide came out of a design problem: how to make the pancreas reveal its enzyme output without passing a tube into the duodenum. Anthony Imondi and colleagues at Rohm & Haas built a synthetic substrate around chymotrypsin's preference for aromatic side chains — a benzoyl-capped tyrosine joined to p-aminobenzoic acid — and reported it in 1972 as a new substrate for a pancreatic exocrine function test. The synthesis coupled ethyl p-aminobenzoate to N-benzoyl-tyrosine using N-methylmorpholine and ethyl chloroformate for activation, then selectively hydrolysed the ester with dimsyl sodium followed by dilute acid. Patents were filed in Germany in 1972 and granted in the United States in 1974, both assigned to Rohm & Haas.
Approval history
Adria Laboratories marketed the peptide as Chymex, and the U.S. Food and Drug Administration approved it in 1983. A dose-ranging crossover study in 47 patients with chronic pancreatic disease and 61 healthy volunteers fixed the practical format: a 500 mg dose with a six-hour urine collection separated the groups best, the lower limit of normal was 57% arylamine recovery, and no healthy volunteer fell below 50%. The agent was well tolerated except at 5 g, where nausea, vomiting and diarrhoea were common. Chymex was withdrawn from the U.S. market in October 1996.
Impact
For about thirteen years bentiromide gave clinicians a tubeless pancreatic test. A five-year series of 588 people, published in 1981, found low PABA excretion in 86% of patients with chronic pancreatitis and 76% of those with pancreatic carcinoma, while 93% of controls and patients with non-pancreatic disease excreted normal amounts. Its weakness matched its appeal: it measured a downstream signal, so it missed mild disease and read intestinal, liver and kidney problems as pancreatic ones. Faecal elastase-1, measured on one stool sample and unaffected by porcine enzyme capsules, displaced it; by 2009 a pancreatic-function specialist described the bentiromide test as generally only of historical interest.
What the research shows
Four decades of single-centre diagnostic-accuracy studies, with no registered randomised trial and no systematic review. The question studied was how well a urine or plasma PABA reading classified patients against a reference standard, not whether testing changed outcomes.
Key findings
- A 500 mg dose with a 0–6 hour urine collection gave the widest separation between disease and health; the lower limit of normal was 57% arylamine recovery, and no healthy volunteer fell below 50%.
- Low urinary PABA identified 86% of chronic pancreatitis and 76% of pancreatic carcinoma cases, while 93% of controls and patients with non-pancreatic disease read as normal.
- Against faecal elastase-1 in 45 patients, the PABA test gave 15 low or borderline results when elastase was normal; 14 of those 15 were traced to a non-pancreatic cause.
What is still unsettled
No registered trial assigned patients to bentiromide-guided care, so nothing shows the test improved outcomes. Sensitivity and specificity estimates come from small series that used different doses, different samples (urine versus plasma at 90 minutes) and different cut-offs, and they cannot be pooled. Whether it ever detected mild insufficiency is doubtful: the 2009 review calls it inaccurate in less advanced disease, and the 2003 comparison traced most abnormal results to non-pancreatic causes. Performance below age 6 is unmeasured.
Open questions
- Why Chymex was withdrawn in October 1996 is not stated in the retrieved record; a withdrawal notice or the sponsor's correspondence would show whether the reasons were commercial or regulatory.
- Would routine use of the PABA excretion index — giving free PABA alongside the peptide — have removed enough false positives for the test to compete with faecal elastase-1?
- How much of the false-positive rate came from intestinal brush-border chymotrypsin-like activity rather than from mucosal absorption or renal handling of PABA?
- No data exist for children under 6; a paediatric dose-ranging study with plasma PABA would show whether the 90-minute cut-off used in older children applies.
More in this index
- Benylin
- Benzilonium bromide
- Benzobarbital
- Benzodioxolylbutanamine
- Benzofuranylpropylaminopentane
- Benzotript
Sources
- Wikipedia: Bentiromide
- ChEMBL compound report card CHEMBL1200368
- PubChem Compound CID 6957673
- Toskes, dose-ranging study of bentiromide, Gastroenterology 1983
- Lang et al., five years of clinical experience with bentiromide, 1981
- Sonwalkar et al., PABA test versus faecal elastase 1, Aliment Pharmacol Ther 2003
- Forsmark, Pancreatic function testing — valuable but underused, 2009
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.