Medicine

Altumomab pentetate

Indium-111 on a mouse antibody made colorectal tumours visible on a scan, and never reached approval

What it is

Altumomab pentetate is a mouse monoclonal antibody against carcinoembryonic antigen (CEA), a protein anchored on the surface of colorectal cancer cells, fastened through a pentetate (DTPA) cage to the gamma-emitting isotope indium-111. It was produced as a kit under the trade name Hybri-CEAKER for radioimmunoscintigraphy: an intravenous injection, then gamma-camera pictures two to three days later. The name altumomab was coined in 1993. No regulator has approved it; it survives in the literature as an investigational imaging agent rather than a medicine anyone can be prescribed.

What it does

Injected into a vein, the antibody circulates, finds CEA on tumour cells and sticks there, and the chelated indium-111 travels with it, so radioactivity collects wherever CEA-bearing tissue sits. Planar and SPECT gamma cameras then map that activity, producing a whole-body image in which tumour deposits stand out as hot spots against the blood pool. In the largest series, 509 patients at 11 nuclear medicine departments received 2-3 mCi (74-111 MBq) with 0.5 mg of anti-CEA fragments and were imaged at 48-72 hours; 73.3% of documented lesions were seen when serum CEA was raised and 53.7% when it was normal. Scans also flagged deposits that computed tomography had missed, and in 35 patients that finding contributed to early detection of a recurrence. The output is an image read for staging and follow-up, not a treatment.

How it works

Target: carcinoembryonic antigen (CEA), a glycosyl-phosphatidyl-inositol-anchored cell-surface glycoprotein of the CD66 family whose blood levels rise in many colorectal carcinomas. The antibody's variable regions bind CEA while the rest of the molecule is mouse protein, which a human immune system can recognise. Pentetate, the chelating conjugate of DTPA, grips the indium-111 ion in a coordinate cage so the metal stays with the antibody instead of dissociating in plasma. Indium-111 decays by electron capture with a half-life of 2.8048 days, emitting gamma photons at 171.3 keV (91%) and 245.4 keV (94%) - energies a standard gamma camera detects and a SPECT detector reconstructs in three dimensions. Because photons leave only while the isotope sits on antibody bound to a tumour cell, activity concentrates where CEA is dense, and imaging at 48-72 hours lets unbound antibody clear so tumour deposits separate from background. Two failures follow from the same chemistry: indium that comes off the chelate is taken up by the liver, and that hepatic uptake masks liver deposits, the limitation reported most often in the clinical series.

Step by step

What it is used for

What to watch for

Interactions

Avoid if

How it was discovered

The antibody belongs to the 1980s attempt to turn monoclonal antibodies into imaging agents. Murine anti-CEA antibodies were conjugated to DTPA so that indium-111 could be added to the vial shortly before injection, and Sorin Biomedica in Saluggia, Italy supplied reagents distributed to nuclear medicine departments across Europe under an Italian National Research Council programme. A first clinical series of 70 patients appeared in 1988, a 509-patient, 11-centre study in 1989, and repeat-dosing safety data in 1992. The name altumomab was coined in 1993; the product carried the trade name Hybri-CEAKER.

Approval history

Nothing was ever approved. The ChEMBL record gives a maximum clinical phase of 1.0 and no first-approval date, and Wikipedia states directly that the drug has not been approved for use. DailyMed holds no label under altumomab or Hybri-CEAKER. An FDA approval letter or an Orange Book listing would settle the question; no such document corresponds to this agent. That is unusual for a compound tested in hundreds of patients: the diagnostic question was answered inside academic nuclear medicine departments, and a commercial filing never followed.

Impact

The 509-patient multicentre study gave antibody imaging its credibility: 73.3% of known lesions appeared on the scan in CEA-seropositive patients, and 35 patients had recurrences picked up early because of an unexpected hot spot. Because the tracer could find deposits that computed tomography missed, the technique entered surgical planning discussions. The product itself never reached a pharmacy, but its formula - a DTPA chelate holding indium-111 on a targeting protein - stayed in use for other indium-111 tracers, including pentetreotide for somatostatin receptor imaging.

What the research shows

Clinical imaging research only, published between 1988 and 1992 and never registered in a public trials database. No randomised study compared the scan with another imaging method.

Key findings

What is still unsettled

The published series name antibody clones - F023C5 and ZCE 025 - rather than the international nonproprietary name, and no registry record ties a specific dataset to altumomab pentetate, so which patients received this exact product cannot be reconstructed. No randomised comparison against computed tomography established that the scan changed outcomes, and no dosimetry standard was agreed. A trial registration record or the original product monograph would settle the mapping.

Open questions

More in this index

Sources

RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.