Medicine
Altumomab pentetate
Indium-111 on a mouse antibody made colorectal tumours visible on a scan, and never reached approval
What it is
Altumomab pentetate is a mouse monoclonal antibody against carcinoembryonic antigen (CEA), a protein anchored on the surface of colorectal cancer cells, fastened through a pentetate (DTPA) cage to the gamma-emitting isotope indium-111. It was produced as a kit under the trade name Hybri-CEAKER for radioimmunoscintigraphy: an intravenous injection, then gamma-camera pictures two to three days later. The name altumomab was coined in 1993. No regulator has approved it; it survives in the literature as an investigational imaging agent rather than a medicine anyone can be prescribed.
What it does
Injected into a vein, the antibody circulates, finds CEA on tumour cells and sticks there, and the chelated indium-111 travels with it, so radioactivity collects wherever CEA-bearing tissue sits. Planar and SPECT gamma cameras then map that activity, producing a whole-body image in which tumour deposits stand out as hot spots against the blood pool. In the largest series, 509 patients at 11 nuclear medicine departments received 2-3 mCi (74-111 MBq) with 0.5 mg of anti-CEA fragments and were imaged at 48-72 hours; 73.3% of documented lesions were seen when serum CEA was raised and 53.7% when it was normal. Scans also flagged deposits that computed tomography had missed, and in 35 patients that finding contributed to early detection of a recurrence. The output is an image read for staging and follow-up, not a treatment.
How it works
Target: carcinoembryonic antigen (CEA), a glycosyl-phosphatidyl-inositol-anchored cell-surface glycoprotein of the CD66 family whose blood levels rise in many colorectal carcinomas. The antibody's variable regions bind CEA while the rest of the molecule is mouse protein, which a human immune system can recognise. Pentetate, the chelating conjugate of DTPA, grips the indium-111 ion in a coordinate cage so the metal stays with the antibody instead of dissociating in plasma. Indium-111 decays by electron capture with a half-life of 2.8048 days, emitting gamma photons at 171.3 keV (91%) and 245.4 keV (94%) - energies a standard gamma camera detects and a SPECT detector reconstructs in three dimensions. Because photons leave only while the isotope sits on antibody bound to a tumour cell, activity concentrates where CEA is dense, and imaging at 48-72 hours lets unbound antibody clear so tumour deposits separate from background. Two failures follow from the same chemistry: indium that comes off the chelate is taken up by the liver, and that hepatic uptake masks liver deposits, the limitation reported most often in the clinical series.
Step by step
- Bind — The antibody's variable regions attach to CEA on the surface of colorectal tumour cells, holding the molecule at the lesion.
- Hold the isotope — Pentetate, a DTPA chelate, wraps the indium-111 ion so the metal cannot drift away from the antibody in plasma.
- Emit — Indium-111 decays by electron capture with a 2.8048-day half-life, releasing gamma photons at 171.3 and 245.4 keV.
- Clear the background — Unbound antibody leaves the circulation over the two to three days between injection and imaging, so tumour activity outweighs blood-pool activity.
- Detect — A gamma camera or SPECT system reconstructs the photons into a map of CEA-bearing tissue; liver uptake of free indium hides hepatic deposits.
What it is used for
- Detecting recurrence of colorectal cancer after surgery
- Staging colorectal adenocarcinoma before operation
- Finding deposits too small or too few for computed tomography
- Repeated follow-up scanning in patients after resection
- Imaging non-colorectal adenocarcinomas
- Diagnosis of colorectal cancer, the use named for the product
What to watch for
- Human anti-mouse antibody (HAMA) response to the murine protein
- Side effects with repeated infusions
- Acute reactions to the injection itself
- Liver uptake of indium-111 hiding hepatic metastases
- Negative scan when the tumour carries little or no CEA
- Missed deposits under 2 cm
- Radiation exposure from an isotope with a 2.8-day half-life
Interactions
- A previous injection of a mouse (murine) antibody — Repeat exposure raised human anti-mouse antibody titres from 30% after one infusion to 64% after a second; in that series the titres did not prevent successful imaging.
- High circulating CEA in the blood — Free antigen binds antibody before it reaches the tumour and forms circulating immune complexes, though tumour uptake of an indium-111 anti-CEA antibody stayed high in patients with the highest antigen levels.
- DTPA, the chelator, given at the same time — The free chelator competed for indium-111, lowering urinary excretion of the isotope and raising liver uptake of radioactivity.
- Unlabelled (cold) anti-CEA antibody given first — Cold antibody increased splenic uptake of the radiolabel and only slightly reduced circulating immune complexes, leaving tumour uptake unchanged.
Avoid if
- Earlier treatment with a mouse antibody: repeat exposure left detectable anti-mouse antibodies in 64% of patients by the second infusion.
- Tumour histology negative for CEA: negative scans tracked with absent CEA on immunohistochemistry, so the antibody has nothing to bind.
- Recurrence confined to the liver: nonspecific hepatic uptake of indium-111 was the most consistent reason hepatic deposits were missed.
How it was discovered
The antibody belongs to the 1980s attempt to turn monoclonal antibodies into imaging agents. Murine anti-CEA antibodies were conjugated to DTPA so that indium-111 could be added to the vial shortly before injection, and Sorin Biomedica in Saluggia, Italy supplied reagents distributed to nuclear medicine departments across Europe under an Italian National Research Council programme. A first clinical series of 70 patients appeared in 1988, a 509-patient, 11-centre study in 1989, and repeat-dosing safety data in 1992. The name altumomab was coined in 1993; the product carried the trade name Hybri-CEAKER.
Approval history
Nothing was ever approved. The ChEMBL record gives a maximum clinical phase of 1.0 and no first-approval date, and Wikipedia states directly that the drug has not been approved for use. DailyMed holds no label under altumomab or Hybri-CEAKER. An FDA approval letter or an Orange Book listing would settle the question; no such document corresponds to this agent. That is unusual for a compound tested in hundreds of patients: the diagnostic question was answered inside academic nuclear medicine departments, and a commercial filing never followed.
Impact
The 509-patient multicentre study gave antibody imaging its credibility: 73.3% of known lesions appeared on the scan in CEA-seropositive patients, and 35 patients had recurrences picked up early because of an unexpected hot spot. Because the tracer could find deposits that computed tomography missed, the technique entered surgical planning discussions. The product itself never reached a pharmacy, but its formula - a DTPA chelate holding indium-111 on a targeting protein - stayed in use for other indium-111 tracers, including pentetreotide for somatostatin receptor imaging.
What the research shows
Clinical imaging research only, published between 1988 and 1992 and never registered in a public trials database. No randomised study compared the scan with another imaging method.
Key findings
- With 2-3 mCi of indium-111 on 0.5 mg of anti-CEA fragments, 73.3% of documented lesions were imaged in CEA-seropositive patients and 53.7% in seronegative patients, with no adverse reactions in 509 patients.
- Sensitivity was 64% for lesions up to 2 cm and 84% for larger lesions, and 35 patients had recurrences detected early after an unexpected localisation.
- Scans were positive in 78% of CEA-seropositive and 64% of seronegative patients, imaged 69% versus 39% of documented lesions, and missed liver metastases because of nonspecific hepatic uptake.
- Repeat infusions every 4-6 months produced anti-mouse antibodies in 30% of patients after the first dose and 64% after the second, with side effects in 16% of those given two or more, while 16 lesions were found in 11 patients whose CT was negative.
What is still unsettled
The published series name antibody clones - F023C5 and ZCE 025 - rather than the international nonproprietary name, and no registry record ties a specific dataset to altumomab pentetate, so which patients received this exact product cannot be reconstructed. No randomised comparison against computed tomography established that the scan changed outcomes, and no dosimetry standard was agreed. A trial registration record or the original product monograph would settle the mapping.
Open questions
- Which published series used altumomab pentetate itself rather than the F023C5 or ZCE 025 reagents that shared its chemistry?
- What absorbed radiation dose did the 2-3 mCi protocol deliver to liver, spleen and red marrow?
- Would the scan have changed surgical decisions compared with modern FDG-PET/CT?
- Why did development stop at phase 1 when the 509-patient study recorded no adverse reactions?
More in this index
Sources
- ChEMBL - Indium In 111 altumomab pentetate (CHEMBL2109040)
- Wikipedia - Indium (111In) altumomab pentetate
- Wikipedia - Indium-111
- Wikipedia - Carcinoembryonic antigen
- DailyMed search - altumomab (no label returned)
- Cancer Research 1989 - multicentre immunoscintigraphy with 111In anti-CEA F(ab')2, 509 patients
- Nuclear Medicine Communications 1988 - 111In anti-CEA F(ab')2 in 70 patients
- 1992 - repeated 111In anti-CEA antibody administration, HAMA and safety
RNAWiki is a reference directory, not medical advice. Check any decision with a pharmacist or clinician.